Skip to content
Open access

Refractive and Vector Outcomes of SMILE Pro with the VISUMAX 800 for High Astigmatism

Jul 2026 · Vision · Vol 10, pp. 45 · 0 citations · 23 references
Medicine

TL;DR

SMILE Pro performed with the VISUMAX 800 provided favorable early 3-month refractive and astigmatic vector outcomes with a satisfactory safety profile in eyes with high astigmatism, evaluated up to 3 months postoperatively.

Abstract

Background/Objectives: High astigmatism remains challenging in keratorefractive lenticule extraction because small errors in centration or cyclotorsion may affect astigmatic correction. This study evaluated early refractive and astigmatic vector outcomes after small-incision lenticule extraction (SMILE) Pro using the VISUMAX 800 in eyes with high astigmatism. Methods: This prospective interventional cohort study was conducted at Cung Hong Son International Eye Hospital, Hanoi, Vietnam. Refractive outcomes, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, astigmatic vector analysis, and intraoperative and postoperative complications, were evaluated up to 3 months postoperatively. Results: A total of 160 eyes from 102 patients were included in the final analysis. The mean age was 23.7 ± 4.7 years, and 63.7% of participants were female. The mean preoperative spherical equivalent (SEQ) was −7.21 ± 2.03 D, and the mean preoperative refractive cylinder was −2.51 ± 0.56 D. Mean postoperative SEQ was −0.10 ± 0.38 D at 1 month and 0.02 ± 0.31 D at 3 months. At 3 months, 99% and 84% of eyes achieved UDVA of 0.8 decimal or better and 0.9 decimal or better, respectively. The mean residual refractive cylinder was −0.52 ± 0.28 D, with 69% and 98% of eyes achieving a residual cylinder ≤0.50 D and ≤1.00 D, respectively. All eyes had an angle of error within ±15°. The safety index was 1.01, and no eyes lost two or more lines of CDVA. Conclusions: SMILE Pro performed with the VISUMAX 800 provided favorable early 3-month refractive and astigmatic vector outcomes with a satisfactory safety profile in eyes with high astigmatism.

Read PDF

Similar papers

Review Open access Sep 2026

Enhanced predictability and axis precision of SMILE Pro, a retrospective analysis of myopic astigmatism correction.

SMILE Pro using the VISUMAX 800 femtosecond laser provides safe and predictable correction of myopic astigmatism with good axis alignment, however, the observed undercorrection in higher cylinders suggests that further optimization of astigmatic nomograms may improve refractive accuracy.

İ. İritaş, Z. Burke · 0 citations
Open access Jul 2026

Comparative Vector Analysis of Astigmatic Changes After Small-incision Lenticule Extraction versus Femtosecond Laser In -situ Keratomileusis

SMILE and FS-LASIK have comparable efficacy, predictability, and safety in correcting myopia associated with high astigmatism and Vector analysis showed comparable results between the two groups in terms of target-induced astigmatism.

M. Phan, Luong Minh Huynh, S. K. Foo · 0 citations
Open access Jul 2026

Early Visual, Refractive, and Astigmatism Vector Outcomes of StreamLight Trans-PRK for High Astigmatism (≥ 2.00 D)

Single-step StreamLight™ Trans-PRK on the WaveLight EX500 platform achieves favorable early refractive, visual, and vector-analytic outcomes in eyes with high preoperative astigmatism, with corneal-plane vector parameters that compare favorably with those reported in the published Trans-PRK literature.

Silvia Victoria Prodescu, Paul Filip Curcă, C. Tătaru et al. · 0 citations
Aug 2026

Visual and Refractive Outcomes Across Low, Medium, and Large Cyclorotation Angles in Myopic LASIK With Automated Cyclorotation Compensation.

Cyclorotational angle magnitude did not significantly impact visual or refractive outcomes in myopic LASIK when using modern laser devices, and limited clinical relevance of cyclorotation degrees in LASIK outcomes is suggested.

Dror Ben Ephraim Noyman, Margarita Safir, Adir C. Sommer et al. · 0 citations
Open access Aug 2026

Safety and Efficacy of Keratorefractive Lenticule Extraction (KLEx) for High Myopia with the CLEAR Platform

Objectives: To assess the safety and efficacy of Keratorefractive Lenticule Extraction (KLEx) in patients with myopia ≥ 5 diopters (D). Methods: Retrospective study of KLEx procedures performed at Siena Eye Laser (Poggibonsi, Italy) with the CLEAR platform of the Ziemer Z8 femtosecond laser. Results: We included 137 ey...

Matteo Posarelli, Lorenzo Azzaro, Stefania V. Fields et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.