PLRS-IC is proposed, a unified dual-calibration framework for chest X-ray representation learning that yields consistent improvements in classification, grounding, and segmentation, validating the necessity of dual-calibration in medical vision-language pre-training.
Abstract
Fine-grained vision-language alignment in chest radiography enables zero-shot classification, grounding, and segmentation without task-specific annotations. However, this alignment is fundamentally hindered by two intertwined sources of ambiguity: projection-induced visual mismatch and patient-agnostic semantic overlap. First, at the local feature level, frontal and lateral radiographs exhibit distinct appearances for the same clinical finding, rendering a shared patch-text similarity geometry inherently suboptimal. Compounding this visual ambiguity is a semantic mismatch during global contrastive optimization, where instance-level objectives penalize cross-patient pairs as strict negatives even when they share identical positive clinical concepts. To address this dual ambiguity, we propose PLRS-IC, a unified dual-calibration framework for chest X-ray representation learning. At the local alignment stage, Projection-Conditioned Low-Rank Residual Similarity (PLRS) dynamically adapts patch-text matching to projection-specific manifolds using a bounded, parameter-efficient low-rank residual. At the global optimization stage, Information-Content-Calibrated Soft False-Negative Suppression (IC-SFNS) leverages a corpus-derived information-theoretic prior to soften the penalty of semantically overlapping negatives without altering original contrastive assignments. Extensive experiments across nine public zero-shot benchmark settings demonstrate that our framework yields consistent improvements in classification, grounding, and segmentation, validating the necessity of dual-calibration in medical vision-language pre-training.
The findings support an integrative recipe rather than a new learning primitive, but they do not establish clinical translation; multi-site prospective validation, blinded multi-rater interpretability evaluation, and domain-shift robustness assessment remain necessary.
Yan-Yun Miao, Xiao-Qin Zhang, Fei Leng et al.· Frontiers in Medicine· 0 citations
Through hierarchical gated co-attention, this approach dynamically aligns image and text representations, addressing the limitations of static fusion and providing a foundation for interpretable, real-time retrieval systems that can accelerate and improve clinical decision support.
An Anatomy-Routed Contrastive Learning for 3D Chest CT (ARC-CT), a region-aware framework that addresses limitations using only reports extracted from reports by an LLM, with no manual annotations or bounding boxes, outperforms both comparable efficient baselines and larger transformer models.
H. Isik, Mehmet Alp Ozaydin, S. Kurugol et al.· 1 citation
Colon3R is presented, a cross-domain semi-supervised framework built on pretrained VGGT that transfers coupled camera, depth, and pointmap geometry from labeled phantom and simulated data to unlabeled in-vivo colonoscopy without requiring target-domain geometric annotations.