Deep learning-based segmentation of non-perfused volume after magnetic resonance guided high-intensity focused ultrasound therapies: a retrospective evaluation on clinical patient data.
Oct 2026· International Journal of Hyperthermia· Vol 43 1, pp.
2711102
· 0 citations· 28 references
Medicine
TL;DR
A deep learning-based automatic NPV segmentation model that demonstrates reliable volumetric assessment with minimal slice-level omission, supporting integration into routine MR-HIFU treatment workflows is developed and clinically evaluated.
Abstract
INTRODUCTION
Non-perfused volume (NPV) is a key imaging biomarker for treatment efficacy in MR -guided high-intensity focused ultrasound (MR-HIFU). In uterine fibroids therapies, the NPV ratio is strongly associated with clinical outcomes and long-term efficacy. We developed and clinically evaluated a deep learning-based automatic NPV segmentation model to facilitate standardized and efficient post-treatment assessment.
Materials And Methods
Contrast-enhanced T1-weighted MR images from 79 patients treated with MR-HIFU were retrospectively analyzed, with NPVs manually delineated as the reference. A 2D U-Net convolutional neural network was optimized using a Tversky loss function (α = 0.7) to prioritize volumetric robustness. Performance was evaluated using similarity metrics (Dice coefficient [DC], 95th percentile Hausdorff distance [HD95]) and clinically relevant measures, including Bland-Altman analysis of volumetric quantification error, precision, recall, slice-level missing rate, and processing time.
Results
In the independent test cohort (n = 12), the model achieved a median DC of 0.900 (IQR: 0.841-0.920) and a median HD95 of 0.42 (IQR: 0.32-0.60) mm. Median absolute NPV quantification error was 4.3 mL (IQR: 2.6-8.4 mL), corresponding to a median relative error of 2.3% (IQR: -2.4% - 10.5%). Precision and recall were 0.909 (IQR: 0.843-0.940) and 0.912 (IQR: 0.881-0.931), respectively, with 2.8% of ground truth-positive slices missed. Average processing time per patient (∼384 slices) was 1-2 min.
Conclusion
The proposed 2D U-Net provides accurate and time-efficient automatic NPV segmentation. Quantitative and clinically oriented evaluation demonstrates reliable volumetric assessment with minimal slice-level omission, supporting integration into routine MR-HIFU treatment workflows.
Purpose To investigate whether selective removal of vascular structures can improve lesion visibility and interpretability in maximum intensity projection (MIP) images derived from dynamic contrast-enhanced MRI. Materials and Methods A retrospective analysis was conducted using breast MRI scans from the Duke-Breast-Can...
Marco Cantone, Tian-Yu Zhang, C. Marrocco et al.· Radiology: Artificial Intell...· 1 citation
3D U-Net provided the most favorable overall performance among the evaluated architectures for intact-cervix cases and support further physician-supervised implementation, followed by multicenter external validation and cohort-level dosimetric assessment.
Chen-Ying Ma, Yi Fu, Lu Zhang et al.· Frontiers in Oncology· 0 citations
This framework provides a tool for direct CPC quantification on QSM that shows strong correspondence with CT-derived volumes, enabling large-scale, longitudinal investigations into the clinical implications of CPC.
Improved quantitative accuracy in CBCT through robust scatter suppression enhances deep learning-based segmentation, particularly for large organs, supporting its role in improving adaptive radiotherapy workflows.
R. Dotel, Farhang Bayat, Jun-Xiao Hu et al.· Physics and Imaging in Radia...· 0 citations
A 3D U-Net-based segmentation framework, NeuroFocusNet, which synchronizes spatial attention, channel recalibration, and attention-gated skip connections within a single volumetric encoder-decoder model is proposed, which is encouraging when considering the feasibility of using NeuroFocusNet as a technically promising...
Faizan Ullah, Z. Abbas, Sergo Gegechkori et al.· IEEE Access· 0 citations
The approach enabled low-error NWU quantification from baseline NCCT without advanced imaging, supporting further prospective clinical evaluation and targeting NCCT-only infarct segmentation across heterogeneous external cohorts, although performance varied across domains.
Linus Britt, M. Nielsen, S. Klapproth et al.· arXiv.org· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.