Abstract

Rapid urban transit development has increased crossings and proximity between railways and gas pipelines, intensifying direct current (DC) stray current interference. Periodic, high-amplitude DC currents from subway operation accelerate corrosion and threaten pipeline integrity. In China, a natural gas pipeline experienced dynamic interference currents up to 976 A/m2, and a sacrificial-anode drainage system proved ineffective. Conventional forced drainage was infeasible because of spatial, construction, and power constraints. This study1 demonstrated the application of a specialized assembled flexible anode integrated with a solar intelligent potentiostat for forced drainage, which proved to be effective, economical, feasible, and flexible, simplifying construction and improving overall performance.