A Planning–Operation Bi-Level Optimization Method for Flexible Power Distribution System Scenarios with Voltage Source Converters Under Flexibility Constraints
High-penetration distributed photovoltaic (PV) generation, energy storage, flexible loads, and voltage source converters (VSCs) are transforming distribution-system operation, making operational flexibility essential in planning. This paper proposes a planning–operation bi-level optimization method for flexible distribution systems with bidirectional flexibility constraints. A multi-resource model is developed for PV, energy storage, interruptible loads, and VSCs. Upward and downward flexibility requirements are quantified from net-load ramping, and the available flexibility of each resource is represented explicitly. The upper level determines PV and energy-storage siting and sizing to minimize annual total cost; the lower level optimizes chronological operation and feeds operating cost, PV curtailment, network losses, voltage deviation, and flexibility shortages back to the planning level. A nested solution strategy combining an improved dung beetle optimization algorithm with operational evaluation was tested on a 58-bus AC/DC hybrid distribution system. Compared with coordinated source-storage planning without flexibility constraints, the proposed scheme reduced annual total cost by CNY 14.8998 million and increased average daily upward and downward flexibility margins to approximately 1.30 MW and 0.38 MW, respectively. The results also show improved PV accommodation and voltage quality, confirming the method’s economic and operational effectiveness under high renewable-energy penetration.
Under high renewable-energy penetration, regional power systems face increasing operational variability caused by wind and photovoltaic generation. Capacity planning for multi-energy complementary systems must therefore consider both investment economy and operation-related reliability costs under practical grid-access...
Bing Yan, Hong-Liang Tian, Jun-Xian Ma et al.· Electronics· 0 citations
Under high renewable energy penetration, the uncertainty of wind and photovoltaic (PV) power outputs increases system operating costs and intensifies the pressure of renewable energy accommodation. To address these challenges, this paper develops a bi-level capacity optimization model with distributionally robust coord...
Energy Storage Systems (ESS) are increasingly recognized as critical enablers of grid flexibility in power systems with high renewable energy penetration. This study presents a comprehensive techno-economic and system-level evaluation of a photovoltaic (PV)-integrated ESS operating under grid-connected and emergency mo...
Ahmed G. Abokhalil, Abdel Rahman Al Qawasmi· WSEAS Transactions on power...· 0 citations
High photovoltaic penetration makes active distribution networks sensitive to voltage deviations, reverse power flow, and feeder operating stress. Energy storage converters can provide two complementary services: active power energy shifting and local, within-step reactive power support for voltage regulation. This pap...
Chang Ye, Xun Xu, Liangli Xiong et al.· Energies· 0 citations
Modern distribution networks increasingly face reverse power flow, heavy loading or overloading, and voltage violations as distributed generation and flexible demand introduce large spatiotemporal variations in active-power injections and withdrawals. This paper proposes a planning-operation consistent DC-AC time-serie...
Li-Fang Wu, Jia-Jia Wei, Qing-Ren Jin et al.· Energies· 0 citations
Planning network reinforcement and flexibility as separate tasks obscures when they substitute for, or complement, one another. We formulate a scenario-hour mixed-integer linear program (MILP) that selects photovoltaic and wind capacity, battery power and energy, energy-neutral demand shifting, photovoltaic-inverter re...
He-Ran Kang, Jie Chen, Yong-Hui Sun et al.· Energies· 1 citation
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.