ABL90 demonstrated the best overall concordance with the reference analyzer in terms of both creatinine measurement and eGFR categorization, followed by i-STAT and pHOx Ultra, which may be attributable to their manufacturer-stated traceability to the NIST reference standards.
Abstract
Point-of-care testing (POCT) devices facilitate rapid creatinine measurement for timely renal function assessment. Accurate creatinine measurement is crucial for estimating glomerular filtration rate (eGFR), which guides clinical decisions including contrast agent administration (eGFR <60 mL/min/1.73m² threshold) and prophylaxis strategies. This study evaluated analytical performance and clinical concordance of three POCT creatinine analyzers.
Three POCT devices were evaluated: NOVA pHOx Ultra (Nova Biomedical), Radiometer ABL90 FLEX (Radiometer Medical), and i-STAT Crea cartridge (Abbott). These were compared against Beckman Coulter AU5800 using an enzymatic method with IDMS-traceable calibration. Venous whole blood samples from 355 adult patients (mean age 62 years, 58% male) were collected over 8 weeks. POCT measurements were performed within 15 minutes of venipuncture. eGFR was calculated using the CKD-EPI 2009 equation and categorized into four clinically relevant stages: =60, 45-59, 30-44, and <30 mL/min/1.73 m². Method comparison employed Passing-Bablok regression and Bland-Altman analysis. Agreement was assessed using weighted kappa statistics.
A total of 355 samples were included after excluding instrument errors or missing data. The correlation coefficients were highest for ABL90 (r = 0.996), followed by i-STAT (r = 0.995), and pHOx Ultra (r = 0.966). Based on allowable total error (±4.2%) at medical decision levels of creatinine (0.6, 1.6, and 6.0 mg/dL), only ABL90 met acceptability across all concentrations. The accuracy of categorical classification in the four stages of eGFR was highest with ABL90 (98.6%), followed by i-STAT (95.2%), and pHOx Ultra (86.5%). Among patients with a reference eGFR = 60 (n = 287), pHOx Ultra misclassified 30 cases (10.5%) as < 60, compared to 8 (2.8%) with i-STAT and 2 (0.7%) with ABL90. In the reference eGFR <30 group (n = 46), pHOx Ultra misclassified four cases (8.7%) as =30, while no misclassification was observed with i-STAT or ABL90.
Among the evaluated POCT devices, ABL90 demonstrated the best overall concordance with the reference analyzer in terms of both creatinine measurement and eGFR categorization, followed by i-STAT and pHOx Ultra. In misclassified cases, all POCT devices tended to underestimate the eGFR. The superior performance of ABL90 and i-STAT may be attributable to their manufacturer-stated traceability to the NIST reference standards. Further investigations are warranted to evaluate the impact of POCT devices on patient management and clinical outcomes.
Background: Point-of-care (POC) blood glucose meters shorten turnaround time for bedside glycemic management, but critical illness introduces physiologic and analytical conditions that can degrade agreement with central laboratory measurements. Objective: To synthesize evidence on the analytical and clinical accuracy o...
C. Amorado, Leah Quinto, Mark Kerwin F. Sayas et al.· International Journal of Hea...· 1 citation
Creatinine is an essential biomarker for assessing kidney function, used widely in the diagnosis and monitoring of acute kidney injury, chronic kidney disease, and treatment related nephrotoxicity. Reliable quantification is therefore critical. Microsampling technologies offer major advantages, including minimall...
Mathias Karlsson, Johan Olausson, Ida Liljekvist et al.· Clinical Chemistry· 0 citations
Differences between the enzymatic and Jaffe creatinine methods may lead to misclassification of CKD stage in children, particularly in infants, but not in adults, as all were classified with normal kidney function.
I. Espinosa, Jeanne Frisby-Zedan, M. Pool et al.· Clinical Chemistry· 0 citations
Established and emerging POCT approaches for kidney assessment in CKD are summarized, with emphasis on creatinine/eGFR and urine albumin-to-creatinine ratio (UACR), and analytical validity from workflow utility and patient-level clinical utility are distinguished.
Atthaphong Phongphithakchai, Kraiyasak Wongna, Ratana Netphakdee et al.· Medical Science· 0 citations
Cystatin C is increasingly recommended for the assessment of kidney function and is particularly useful for estimating glomerular filtration rate (eGFR) when creatinine-based measurements are unreliable, including in individuals with altered muscle mass or other non–GFR determinants of creatinine. Despite its cli...
Mildred Martey, C. Omosule· Clinical Chemistry· 0 citations
Abstract Objectives We validated the analytical performance and clinical diagnostic efficacy of the eCL8000i point-of-care testing (POCT) system for high-sensitivity cardiac troponin T (hs-cTnT), following the standardized verification protocol for hs-cTnT POCT assays. Methods A two-phase evaluation was conducted: Phas...
Fei Ding, Yu-Yao Li, Jia Li et al.· Journal of Laboratory Medici...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.