Skip to content
Open access

Thermo-optic characterization of optically similar aqueous solutions using SMS/MMI fiber sensor

Aug 2026 · Journal of Physics D: Applied Physics · Vol 59, pp. 365104 · 0 citations · 43 references
Physics

Abstract

Multimode interference (MMI) fiber sensors with singlemode–multimode–singlemode (SMS) structures based on no-core multimode fiber (NC-MMF), have been widely employed for refractive index (RI) sensing of liquid samples due to their simplicity, low cost, and high sensitivity to changes in the immersion medium. In this work, we investigate the temperature-dependent spectral response of an SMS/MMI fiber sensor immersed in aqueous solutions with closely similar RI. Aqueous solutions of tris(hydroxymethyl)aminomethane (Tris), urea, and fructose were selected as model analytes because they exhibit nearly indistinguishable RI properties under conventional room-temperature conditions. The thermo-optic response of the sensor was studied by performing controlled temperature sweeps from 25 °C to 45 °C. Experimental results reveal that, although the three solutions produce comparable concentration-dependent refractometric responses, they exhibit distinct nonlinear temperature-dependent spectral shifts. To explain this behavior, a numerical model based on MMI theory was developed, showing that the observed nonlinearities arise from the intrinsic nonlinear dependence of the MMI peak wavelength on the RI of the immersion medium. Consequently, small thermo-optic variations in the liquid samples are transformed into measurable nonlinear spectral signatures. The results demonstrate that SMS/MMI fiber sensors can provide access to thermo-optic information that is not available through conventional single temperature refractometry. The proposed approach highlights the potential of MMI devices as simple optical platforms for thermo-optic characterization of aqueous media and for the study of temperature-dependent optical properties in liquid samples with closely similar RI.

Read PDF

Similar papers

Open access Oct 2026

High-sensitivity fiber temperature sensor based on a sodium silicate-filled SNS structure

A highly sensitive liquid-sealed single-mode-no-core-single-mode (SNS) fiber temperature sensor based on a sodium silicate solution (Na2O·nSiO2) is proposed. A sodium silicate solution with a refractive index (RI) closer to that of the no-core fiber (NCF) and a high thermo-optic coefficient (TOC) was introduced into th...

Si Cheng, Xiao-Lei Bai, Ye-Han Liu et al. · 0 citations
Oct 2026

Capillary-confined photonic crystal sensor for dual-mode monitoring of PFOA.

Herein, we report a capillary-confined, high-concentration self-assembly strategy that overcomes the persistent limitations of conventional photonic crystals, including mechanical fragility, slow assembly, and angle dependence. Specifically, the robust capillary housing protects the photonic crystal from mechanical dam...

Yang-Yang Liu, Dan Wu, Jiong Guo et al. · 0 citations
Open access 2026

Fiber-Optic SPR Sensor Based on MMF-SMF-MMF Structure for Detection of Compositional Variations in Diesel Fuel

The article presents a fiber-optic surface plasmon resonance sensor based on a multimode–single-mode–multimode fiber structure for detecting compositional variations and differentiating diesel fuel grades. The sensor design, modelling approach, and experimental implementation are described. To enhance the sensitivity a...

A. A. Zykina, S. Plyastsov, I. Gladskikh et al. · 0 citations
Open access 2026

Microfiber Single Loop Resonator as a Liquid Sensor: Wavelength-Dependent Response to Cetirizine Hydrochloride Solution Volume at 1310 nm and 1550 nm

Liquid sensing is needed in environmental, pharmaceutical and industrial settings, yet most of the devices on the market are electronic and tend to wear out quickly in wet conditions. This study reports a preliminary feasibility investigation of a simple microfiber single loop resonator (MSLR) made from standard single...

Mehala Elango, M. Johari · 0 citations
Conference 2026

Refractive Index Measurement of Biomedical Fluids and Novel Photopolymers Using Low-Coherence Interferometry

In this paper, a low-coherence interferometric method for non-contact refractive index measurement is experimentally investigated with emphasis on biomedical samples. The experimental setup is based on a fiber-optic configuration, where the optical path difference (OPD) is obtained from the recorded interference spectr...

Blanka Kuzmanović, Magdalena Atanasovska, A. Joža et al. · 0 citations
Open access Oct 2026

Ultra-High Sensitivity Terahertz Dual-Parameter Sensing Based on Eccentric-Core Photonic Crystal Fiber

To overcome the temperature cross‑sensitivity common in single‑parameter sensing, as well as the insufficient sensitivity and limited penetration depth of conventional near‑ and mid‑infrared sensors, this paper proposes an ultrahigh‑sensitivity THz dual‑parameter sensor based on an eccentric PCF. The proposed structure...

Yan-Yan Wang, Wei-Hua Shi, Hui Zhao et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.