Skip to content
Preprint

Sliding-scale Insulin Does Not Control Steroid-induced Hyperglycemia in a Non-diabetic Patient, No Matter How You Tune It

Oct 2026 · 0 citations · 23 references
Engineering Computer Science Biology

TL;DR

The sliding scale is proposed to be replaced with a continuous insulin infusion co-delivered with the dextrose and adjusted once a day on mean glucose, the one quantity four-hour monitoring can measure.

Abstract

Sliding-scale insulin is the default hospital response to high blood glucose. Its correction factor was designed for patients who make no insulin, yet it is routinely ordered for patients whose pancreas still works, including those on high-dose steroids. We treat the sliding scale as what it is, a proportional controller sampled every four hours, acting on a patient who already contains a working glucose controller of her own. We test it in a non-diabetic adolescent on high-dose corticosteroids and parenteral nutrition, and in 4,995 virtual patients. It fails for three structural reasons, and no choice of correction factor fixes any of them. First, the patient's own loop settles in 11.5 minutes while injected insulin takes 64 minutes to peak, so most of each dose simply replaces insulin she would have secreted; in simulation the ordered scale moved her mean glucose by less than 1.5 mg/dL. Second, one unit lowers glucose twice as much at 110 mg/dL as at 190, so any correction factor strong enough to work when glucose is high overshoots when it is low; in 99.5% of virtual patients no constant factor does both. Third, four-hour sampling is far below the Nyquist rate, so successive readings are uncorrelated and each dose responds to a value that does not persist. Even the argument that correction doses rest the beta cells, taken on its own terms, favors continuous delivery. We propose replacing the scale with a continuous insulin infusion co-delivered with the dextrose and adjusted once a day on mean glucose, the one quantity four-hour monitoring can measure.

View source

Similar papers

Review Open access Oct 2026

Insulin Icodec in India: A Narrative Review of the First Once-Weekly Basal Insulin

Insulin icodec is the first once-weekly basal insulin. Three amino acid substitutions and a fatty acid side chain allow it to bind reversibly to albumin, giving a half-life of 196 hours, so one injection covers a week. Across the six ONWARDS phase 3a trials, icodec was non-inferior to daily basal insulins on HbA1c redu...

Rahul Garg · 0 citations
Review Open access Oct 2026

Glycemia Regulation in Type 1 Diabetes Using Artificial Pancreas Systems: One Decade Review of Positive Control Approaches

An artificial pancreas (AP) is a biomedical device that mimics the natural glucose-regulation process carried out by a healthy pancreas. This device consists of three parts: a continuous glucose monitor (CGM), a control algorithm, and an insulin pump. These three parts work together by continuously monitoring blood glu...

L. T. Rasheed, A. Alaraji, T. Mohammadridha · 0 citations
Open access Nov 2026

O-11: Once-Weekly insulin efsitora achieves comparable A1C reduction to daily insulin therapy

Type 1 Diabetics requires Insulin to keep the blood glucose levels within normal range as body no longer produces Insulin and requires exogenous source.Insulin efistora is a new insulin preperation used once weekly to treat Diabetes. To determine the efficacy of once weekly Insulin Efistora in Young adults...

F. Abbas · 0 citations
Open access Nov 2026

P-501: Insulin pump therapy improves glycemic control in an adolescent with exocrine pancreatic insufficiency and unstable carbohydrate absorption

Diabetes associated with exocrine pancreatic insufficiency is challenging to manage, especially when intestinal absorption is irregular. In such cases, multiple daily injections may fail to match insulin delivery to unpredictable carbohydrate absorption, leading to marked glycemic variability. To describe...

D. Alencar de Menezes Athayde, H. H. T. de Carvalho, J. C. Cavalcanti de Oliveira et al. · 0 citations
Open access Nov 2026

P-438: Comparison of continuous glucose monitoring and self-monitoring of blood glucose for glycemic control in pediatric type 1 diabetes mellitus

Type 1 Diabetes Mellitus (T1DM) is a chronic endocrine disorder requiring lifelong insulin therapy and vigilant glucose control. Being a chronic illness, monitoring and tight glycemic control has always been a matter of concern for both physicians and patients, especially when it comes to children and adolescents...

M. Abid, M. Ibrahim, M. Gul et al. · 0 citations
Open access Oct 2026

A data-driven system for insulin pump dosing in type 2 diabetes: development, prospective evaluation and clinical applicability

Open-loop insulin pump therapy depends on clinical expertise for dose initiation and titration. We developed a long short-term memory-based system, using 1738 treatment courses from 1641 patients with type 2 diabetes for initial prescribing and daily basal and bolus titration. Patient-grouped five-fold validation showe...

L. Cai, S. Huang, Y. Cao et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.