A scenario analysis based on plant operating data further indicated the potential to reduce external phosphorus input by lowering reliance on the existing phosphorus-containing corrosion inhibitor by lowering reliance on the existing phosphorus-containing corrosion inhibitor.
Abstract
Maintaining microbial corrosion protection in industrial cooling water is difficult because water chemistry changes during operation and introduced bacteria must coexist with indigenous microorganisms. A 28-d rotating coupon experiment was conducted using actual makeup water from a coal-fired power plant. Four treatments were compared: untreated water (R0), carrier only (R1), a 1:1 mixture of Bacillus cereus BC3 and Bacillus subtilis BS2 without a carrier (R2), and the same inoculum with a suspended PET carrier (R3). R2 and R3 were inoculated once at day 0. R1 did not significantly reduce the day-28 corrosion rate relative to R0. R2 showed a larger early increase in interfacial resistance, whereas R3 maintained higher charge transfer resistance and film resistance during the middle and later stages. At day 28, corrosion inhibition efficiencies were 44.51% for R2 and 60.67% for R3. The relative abundance of Bacillus on the steel declined more slowly in R3. At the endpoint, R3 had a more continuous surface layer, higher surface Ca, stronger carbonate signals, and higher urease and carbonic anhydrase activities. Metagenomic and metabolomic profiles further distinguished R3 from R2. The corrosion rate of R3 was similar in magnitude to the plant monitoring value under the routine low-phosphorus treatment program, although the operating conditions differed. A scenario analysis based on plant operating data further indicated the potential to reduce external phosphorus input by lowering reliance on the existing phosphorus-containing corrosion inhibitor.
This study investigated how progressively enhanced oxygen supply affected mixed-phenolic-compound removal and microbial niche differentiation in biofilm reactors. Four 250 mL reactors containing suspended sludge and polyurethane (PU) carriers treated synthetic wastewater with six phenolic compounds at total phenol (T...
Maintaining chemical and biological water stability throughout reclaimed water distribution systems (RWDSs) is critical for safe water reuse. This study conducted a 140-d continuous investigation of simulated RWDSs equipped with ductile iron and polyethylene pipes under influents pretreated by biological activated carb...
Yuan Bai, Song Xue, Yin-Hu Wu et al.· Journal of Environmental Man...· 0 citations
Sludge-based bioaugmentation is a promising and practical strategy for treating refractory N,N-dimethylformamide (DMF) wastewater, yet the ecological basis underlying its stability under intense DMF loading remains unclear. Here, two parallel anaerobic sequencing-batch reactors were operated for 60 days under progressi...
Ling Jiang, Zhe Yang, Jia-Lin Li et al.· Bioresource Technology· 0 citations
The biofilter‑microbial fuel cell (BF‑MFC) coupled process is promising for rural wastewater treatment due to low cost and small footprint, but most studies target Class I B discharge standards. This work uses pyrite (FeS2) as anode packing and systematically optimizes HRT, anode number, pyrite ratio, and spatial distr...
Hong-Xiao You, Ya-Qun Wu· Journal of Physics, Conferen...· 0 citations