Oct 2026· IEEE Sensors Journal· Vol 26, pp. 29451-29464· 0 citations· 63 references
TL;DR
Findings indicate that multisensor PPG configurations with motion compensation are necessary for robust head-mounted cardiovascular monitoring, with no single site being optimal across both conditions.
Abstract
Measuring heart rate (HR) and HR variability (HRV) is critical for assessing the cognitive load in wearable health monitoring and extended reality applications. Realizing the continuous measurement of these parameters requires hands-free sensing solutions that minimize interference with daily activities. The aim of this study is to identify the best configuration of anatomical location on the head and wavelength for making accurate measurements of HR and HRV using a noninvasive photoplethysmography (PPG) sensor, while the wearer is at rest or during walking. To identify the optimal placement, we analytically compared three head locations (temple, supraorbital, and glabella) combined with three wavelengths [red, infrared (IR), and green] and validated the results against an electrocardiography (ECG) reference. We recorded data for 16 participants during 5-min sessions under both static and walking conditions. Temple–IR achieved clinical-grade accuracy for HR during static conditions (5.5% error), whereas glabella–IR produced the most accurate results during walking. Notably, the performance of the three wavelengths converged during motion, as the static advantage of IR disappeared. Head-mounted PPG demonstrated statistical equivalence to finger sensors across both conditions. Choice of sensor location depends on activity, with no single site being optimal across both conditions. These findings indicate that multisensor PPG configurations with motion compensation are necessary for robust head-mounted cardiovascular monitoring.
In clinical settings, every minute of delay in treating a cardiopulmonary emergency can reduce a patient's chance of survival by up to 10%. Photoplethysmography (PPG) is a low-cost, noninvasive method widely adopted in both clinical, and consumer settings to monitor cardiopulmonary signals. Therefore, clinical PPG puls...
Karlen Aleksanyan, Xue Xu, Zheng Liu et al.· IEEE Sensors Letters· 0 citations
Continuous non-invasive health monitoring requires wearable devices capable of capturing synchronized, multi-parametric physiological data without compromising user comfort or signal integrity. However, existing platforms often suffer from insufficient accuracy in complex modalities such bioimpedance. To address these...
J. P. de León, J. R. Beltrán, D. Asiain· Italian National Conference...· 0 citations
Heart rate (HR) is a valuable and widely used indicator of cardiac health. Electrocardiographic (ECG) recordings are the medical gold standard for HR estimation. However, the growing demand for mobile cardiac monitoring prompted investigation of other sensing modalities. Photoplethysmographs (PPGs) and accelerometers (...
J. Kršić, Mirjana G. Stojanović, M. Miletić et al.· IEEE Sensors Journal· 0 citations
Wearable devices have made continuous monitoring of basic vitals such as Heart Rate (HR), Heart Rate Variability (HRV), oxygen saturation (SpO2), single-lead electrocardiogram (ECG) routine, but the advanced hemodynamic markers needed to anticipate cardiovascular events remain confined to the clinic. Stroke Volume (SV)...
Vignesh Ravichandran, A. Balaji, Andrea Ferlini et al.· Proceedings of the 2026 ACM...· 0 citations
The widespread adoption of wearable devices has created new opportunities for continuous monitoring of physical activity, cardiovascular health, and sleep patterns. However, it remains an open question to what extent the physiological and kinematic data provided by commercial smartwatches can be considered accurate and...
János Dávid Balogh, Attila Adamkó· Proceedings of the 13th Inte...· 0 citations
Wearable photoplethysmography (PPG) can return a plausible heart rate (HR) after motion or poor optical coupling has made the measurement unreliable. We treat HR reporting as a reliability-control problem and introduce an interpretable signal quality index (SQI) layer that reports coverage and residual error. On PPG-Da...