Skip to content

Comparing the Single Maddox Rod Test to the Alternate Cover Test in Normal Individuals.

Sep 2026 · Journal of Binocular Vision and Ocular Motility · pp. 1-5 · 0 citations · 9 references
Medicine

Abstract

Purpose

The single Maddox rod test (SMRT) is a rapid subjective method for detecting ocular misalignment. In this study, we compared the prism single Maddox rod test (PSMRT) to the prism alternate cover test (PACT) in normal individuals to see if there was any disagreement.

Methods

Ocular alignment was measured at distance and near with the PSMRT and PACT in 52 normal participants. Secondary measurements included visual acuity, near point of convergence, and stereoacuity.

Results

The difference between each participants' measurements at near (ΔX') was 4.44 ± 3.87 Δ (p < .001) meaning each participant was an average of 4.44 Δ more exophoric at near with the PSMRT compared to their measurement at near with the PACT. There was no significant difference between PSMRT and PACT at distance (-0.09 ± 1.33 Δ (p > .5)).

Discussion

Among visually normal participants, the PSMRT measures more exophoria at near than the PACT. This difference may affect the interpretation of near alignment in various clinical settings, especially when evaluating patients with symptoms suggestive of convergence insufficiency. The PSMRT should be used with caution and be confirmed with the PACT when clinically indicated.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.