Operating-Spectrum Optimization of Water-Intake Pump Retrofits Under Hydrological Variability: Integrating Hydraulic Performance, Energy Use, and Carbon Cost

Sep 2026 · Water · 0 citations · 22 references

Abstract

A pump selected at one duty point may perform poorly over a full year because river level, pipe resistance, demand, and the number of running units all change the operating point. This paper compares discrete retrofit options for a water-intake pumping station using a documented steady-state hydraulic model, pump performance surfaces, and a representative hydrological year (RHY). The analysis distinguishes field observations from engineering calculations, reconstructed operation, and economic scenarios. Two pre-retrofit DCS snapshots give back-calculated pump hydraulic efficiencies of 73% and 65%. These values cannot be compared directly with the 87.8% factory efficiency because the operating conditions and test boundaries differ. The RHY comprises 35,136 modelled 15 min intervals and is not presented as measured SCADA. Using the engineering-record estimate of a 40 kW reduction per active pump, annual electricity use falls from 3232.2 to 2398.7 MWh, corresponding to 833.6 MWh (25.8%) of modelled savings. A 30–50 kW sensitivity range gives savings of 625.3–1042.1 MWh (20.7–30.3%). The redesigned pump has a reconstructed mean hydraulic efficiency of 86.72%, and 93.3% of delivered volume is conveyed at efficiencies above 86%. In the anonymous life-cycle screen, the retained-interface redesign has the lowest central cost at 62.36 RMB/t CO2, while deeper replacement becomes competitive only at higher shadow carbon prices. The findings show the value of matching a retrofit to the annual operating spectrum, although full-year field data are still needed to verify the predicted savings.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.