Skip to content
Open access

Neck vs Head Interspace Ratios in Hallux Valgus: A Reliability Analysis of First Metatarsal Radiographic Measurements.

Oct 2026 · Journal of Foot and Ankle Surgery · 0 citations · 26 references
Medicine

TL;DR

The findings suggest that NIR may represent a more robust radiographic parameter and support further clinical investigation before its use in surgical decision-making for hallux valgus.

Abstract

Background

The relationship between the intermetatarsal space and first metatarsal width has been proposed as a radiographic parameter for surgical planning in hallux valgus. However, the reproducibility of the previously described Head Interspace Ratio (HIR) has not been formally evaluated, limiting confidence in its clinical application.

Purpose

To compare the intraobserver and interobserver reliability of the Head Interspace Ratio (HIR) and the newly proposed Neck Interspace Ratio (NIR). STUDY

Design

Retrospective cross-sectional reliability study.

Methods

Fifty standardized weight-bearing anteroposterior radiographs were independently evaluated by three observers with different experience levels during two sessions. Reliability was assessed using intraclass correlation coefficients (ICC). Agreement and measurement precision were evaluated using Bland-Altman analysis, standard error of measurement, and minimal detectable change at the 95% confidence level.

Results

NIR demonstrated good to excellent intraobserver reliability (ICC, 0.876-0.963) and good interobserver reliability (ICC = 0.886; 95% CI, 0.826-0.929). HIR showed greater variability, with good reproducibility for the two more experienced observers but poor reliability for the least experienced observer (ICC = 0.236; 95% CI, -0.043 to 0.481). Interobserver reliability was lower for HIR (ICC = 0.464; 95% CI, 0.276-0.633). Measurement error was lower for NIR than HIR (MDC95, 0.167 vs 0.277).

Conclusions

Under the conditions evaluated in this study, NIR demonstrated greater reproducibility and lower measurement error than HIR. These findings suggest that NIR may represent a more robust radiographic parameter and support further clinical investigation before its use in surgical decision-making for hallux valgus.

Read PDF

Similar papers

Open access Aug 2026

MRI-Derived Scapular Superomedial Angle and Acromial Morphology: A Retrospective Cross-Sectional Reliability and Morphometric Association Study

Background/Objectives: The magnetic resonance imaging (MRI)-derived scapular superomedial angle (SMA) may serve as a continuous descriptor of scapular geometry. We evaluated whether SMA is associated with acromial morphology, examined SMA and subacromial space (SAS) across acromial categories, and quantified measuremen...

Sami Kandefer, Volkan Gür, Mehmet Burak Gökgöz et al. · 0 citations
Open access Sep 2026

Interobserver Agreement Between Orthopedic Surgeons and Radiologists in Cobb Angle Measurement on Plain Radiographs in Patients with Scoliosis

Interobserver agreement in Cobb angle measurements was found to be low and the need for standardized measurement protocols in clinical practice is emphasized, and digital tools and artificial intelligence–assisted methods may improve measurement reliability.

Habip Eser Akkaya, Mithat Temizer, Omer Kocak et al. · 0 citations
Open access Sep 2026

Radiological Changes After Craniovertebral Junction Stabilization: Evaluation of Established Measurements and Novel Cranial and Caudal Anterior Atlantodental Interval Parameters

Established craniometric distances and separate cranial and caudal AADI measurements demonstrated postoperative radiological changes with good-to-excellent observer reliability and segmented AADI and angular parameters showed different patterns of postoperative change; however, their relative responsiveness was not dir...

Nurullah Kösmene, Efecan Erişken, I. E. Sevin et al. · 0 citations
Open access Oct 2026

FP1.8 Is the Anterior Wall Index a Reliable Surrogate of Anterior Hip Coverage? Correlation With Anterior center Edge Angle and Interobserver Reliability Study

Abstract ICLB01 - The Instability Masterclass: Correcting Bone, Biology, and Bad Outcomes, Session Room 6 (BMCC Level 3), October 8, 2026, 10:30 - 12:30 Introduction Accurate assessment of anterior femoral head coverage is essential in hip preservation surgery. The anterior center-edge angle (ACEA), measured on false-p...

Orthopaedic Surgeon Pedro Pablo Amenábar Md, Martin Hettich, Orthopaedic Surgeon Pedro Pablo Amenábar Md et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.