Sep 2026· 2026 International Conference on Smart Energy Systems and Technologies (SEST)· pp. 1-6· 0 citations· 29 references
Abstract
The increasing penetration of converter-interfaced resources is fundamentally changing the relationship between grid strength and system stability. Conventional metrics, such as the Short-Circuit Ratio and its variants, primarily reflect network stiffness but fail to capture control-driven and dynamic interactions introduced by inverter-based resources.This paper presents a comparative assessment of grid strength evaluation methods in converter-dominated distribution networks, focusing on grid-following and grid-forming inverters with different control strategies. A unified simulation framework is used to evaluate short-circuit-based metrics, impedance-based methods, and time-domain (EMT) dynamic responses under weak and islanded grid. The results show that SCR-based metrics remain insensitive to converter control strategies, even when system dynamics differ significantly. In contrast, impedance-based metrics provide insight into frequency-dependent interactions and reveal controller-induced differences, particularly under very weak conditions. However, these methods are limited to small-signal analysis and do not represent large-signal disturbances or operating-point effects. EMT simulations demonstrate that dynamic stability is strongly influenced by converter control and operating conditions.Based on these findings, the paper proposes a multidimensional interpretation, integrating voltage stiffness, network coupling, dynamic response, control sensitivity, and frequency interaction. The results highlight that no single metric is sufficient to characterize grid strength in converter-dominated systems, and a combined assessment approach is required.
Islanded power systems are inherently challenging to operate due to limited interconnection, low inertia, and weak short-circuit strength. As renewable and inverter-based resources replace synchronous machines, these challenges worsen, causing faster frequency deviations, greater voltage volatility, and higher risk of...
Alexander Novikov, Luis A. Garcia-Reyes, Anup Joshi et al.· 0 citations
Short-circuit-ratio-type indices describe the static fault level of a connection point but not how much network weakening, dispatch growth, or control-parameter drift a heterogeneous multiport system can absorb before a damping threshold or a stability limit is reached. This paper defines a dynamic system strength for...
Ji-Shuo Qin, Fan Li, Han-Qing Liang et al.· Electronics· 0 citations
Over the years, Dominion Energy Virginia (DEV) has experienced recurring power quality disturbances, including voltage and power oscillations, particularly in areas with significant inverter-based generation. While these phenomena suggest a potential relationship to system strength, no definitive correlation has yet be...
Mohammed N. Khamees, G. Ilunga, Zhong-Xia Zhang et al.· arXiv.org· 0 citations
Unlike single-converter grid-connected systems and multi-converter grid-forming (GFM) systems operating in islanded mode, grid-connected multi-converter systems comprising parallel grid-following (GFL) and GFM converters exhibit more complex internal interactions. The negative damping of GFL converters and the low-freq...
Cong Wang, Wei Zhao, Yu-Zhi Wang et al.· Energies· 0 citations
Grid-forming (GFM) converters are widely recognized as a key technology for enhancing the stability of power systems with high renewable penetration. Among various GFM strategies, Virtual Oscillator Control (VOC) offers fast dynamic response and inherent self-synchronization. However, under reactive power overload, the...
Yi-Fan Cai, Chun Miao, K. Ma et al.· 2026 6th International Confe...· 0 citations
The voltage and frequency support capability of grid-forming converters under weak-grid conditions makes them key equipment for power systems with a high share of renewable energy, yet the coupling between their control parameters and grid strength still lacks a boundary-oriented description suitable for parameter tuni...