Comparative analysis of steady-state and dynamic models for grid-connected photovoltaic farm performance monitoring: A case study of Huawei SUN2000-60KTL-M0 inverter
Aug 2026· Energy Storage and Conversion· 0 citations· 26 references
Abstract
This study evaluates the solar-to-electrical energy conversion performance of a 63.24 kWp grid-connected photovoltaic (PV) farm equipped with a Huawei SUN2000-60KTL-M0 (60 kW) inverter by comparing a steady-state diagnostic model against a dynamic observability assessment. A single-instant snapshot of 12 PV strings on 26 June 2026 identified three non-producing strings (PV6, PV7, PV8), reducing string availability to 75.0% and causing an instantaneous DC power shortfall of approximately 6.0 kW (23.6% of currently achievable capacity). Inverter DC-to-AC conversion efficiency was 98.72% and the observed daily-equivalent capacity factor was 15.48%, both computed directly from measured values. Performance Ratio is reported as not evaluable due to the absence of temporally overlapping plane-of-array irradiance data. The dynamic assessment evaluates day-to-day energy temporal variability and historical hourly weather variability from measured June 2026 and 2020–2025 records (mean absolute daily ramp 12.66%, daily energy CV 19.45%), while sub-minute electrical transient characteristics remain not evaluable owing to the lack of sub-minute electrical logging. A Model Observability Score (MOS) and Data Resolution Adequacy Index (DRAI) are computed from an a priori parameter registry. The steady-state model achieves an MOS of 87.5% (7 of 8 applicable parameters), while the dynamic model achieves 25.0% (4 of 16), with the gap concentrated in the electrical-transient domain and attributable to instrumentation limitations. A phased instrumentation roadmap is proposed. The findings provide a transparent, auditable template for determining appropriate monitoring depth in tropical grid-connected PV operations and maintenance practice.
This study presents a comparative techno-economic assessment of a standalone residential solar photovoltaic (PV) system with LiFePO₄ lithium-ion battery storage designed to meet a relatively high household electricity demand of 19.8 kWh/day across Abuja (Nigeria), Beijing (China), and Washington DC (USA). PV system sim...
Anthony Chibuike Ohajianya, Obinna Duru, B. Okereke et al.· Journal of Renewable Energy...· 0 citations
Rooftop solar photovoltaic (RSPV) systems are increasingly recognized as a vital component of the decentralized energy transition, enabling on-site electricity generation that minimizes transmission losses while advancing institutional sustainability goals. This paper presents a simulation-based techno-economic and env...
Aslanie Limbona, Raşit Atelge· International Journal of Ene...· 0 citations
Energy management is a key factor in the reliability and performance of photovoltaic (PV) systems coupled with battery storage for rural electrification. Unlike studies based on representative days, this work investigates the operation of a PV–battery system over a continuous 28-day period (672 h) to assess the influen...
Souleymane Soumah, Mouhamadou Ndiaye, M. A. Camara et al.· World Journal of Advanced Re...· 0 citations
Reliable and sustainable electricity supply remains a major challenge for public infrastructure in Sub-Saharan Africa, where frequent grid interruptions and abundant solar resources create favorable conditions for hybrid renewable energy systems. This study presents a comprehensive techno-economic assessment of a hybri...
To reduce dependence on diesel-based power generation and associated carbon emissions, the Government of Timor-Leste has initiated the development of a 15 MWp on-grid solar photovoltaic (PV) power plant within the EDTL RAEOA operational area. While this initiative supports the national clean energy transition and risin...
Jose Alexandre Bana, Abraham Lomi, Widodo Pudji Muljanto et al.· Sinergi· 0 citations
The integration of renewable energy systems in institutional buildings requires optimized photovoltaic (PV) designs that consider local climatic conditions and technical constraints. This research evaluates the feasibility and operational performance of a proposed 23.8 kWp (24 kW nominal AC) on-grid rooftop solar power...
Nur Iksan, Pamor Gunoto, Nurham Ambo Rappe et al.· International Journal of Rec...· 0 citations