Oct 2026· Current Directions in Biomedical Engineering· Vol 12, pp. 624 - 627· 0 citations· 8 references
TL;DR
The results showed that plasma behavior and electrical interaction with the target are strongly influenced by operating and design parameters, especially gas flow rate, treatment distance, counter-electrode position, and the number of counter-electrode windings.
Abstract
Abstract Cold atmospheric plasma has emerged as a promising technology for medical applications, particularly for chronic wound treatment. In this work, a novel portable argon cold plasma treatment unit is presented, operating at a low gas flow rate of 1 L/min and generating a stable plasma plume of up to 8 mm. The study focused on the implementation and electrical characterization of the electrode configuration with regard to patient leakage current (PLC) according to DIN EN 60601-1. The measurements revealed PLC values well below the safety limit of 100 μA for all investigated conditions. Furthermore, the results showed that plasma behavior and electrical interaction with the target are strongly influenced by operating and design parameters, especially gas flow rate, treatment distance, counter-electrode position, and the number of counter-electrode windings. The study therefore demonstrates both the feasibility of a low-flow portable argon plasma source and the importance of geometrical optimization for safe and efficient medical device design.
This study introduces a compact and handheld cold atmospheric plasma (CAP) device for precision surface treatment and antibacterial applications. The device operated on a 3.7 V lithium-ion cell and featured a high-voltage module generating 20 kV to ionize argon gas through a needle-ring electrode structure, ensuring ef...
Chi Tran Nhu, Minh Do Trung, Hiên Lê Thị et al.· Engineering Research Express· 0 citations
The development and testing of a portable, battery-powered cold plasma device for the treatment of skin indications - with a particular focus on its use in burn medicine, points the way forward within plasma medicine and the development of portable therapy solutions.
Yves Weiland, D. Feili· Current Directions in Biomed...· 0 citations
Cold atmospheric plasma (CAP) has emerged as a promising tool in biomedical applications, including the treatment of precancerous neoplasias. The clinical application of low-thermal argon plasma devitalization (ltAPD) using electrosurgical argon plasma coagulation (APC) probes demonstrated significant clinical efficacy...
Marcel Arnholdt, Laura Awakowicz, Bastian Kogelheide et al.· ACS Applied Materials and In...· 0 citations
The focus of this study is on generating hollow cathode discharge (HCD) plasma inside three types of polymer tubes, resulting in the activation of the tubes’ inner surfaces. To achieve this goal, both theoretical calculations and experiments were carried out to prove that the adopted methodology was feasible. By applyi...
Jang-Hsing Hsieh, Jyh-Wei Lee, Chuan Li et al.· Polymers· 0 citations
Cold atmospheric pressure plasma jets are widely used for surface treatment and plasma-assisted processing. However, simultaneous plasma transport and spatial scaling remain challenging for existing plasma jet concepts. In this work, a novel linear-geometry cold APPJ concept based on a floating metallic mesh electrode...
V. Udachin, A. Tillmanns, Christof Zickenheiner et al.· Journal of Physics D: Applie...· 0 citations
This study details the design and construction of a compact electrothermal vaporization-atmospheric pressure glow discharge atomic emission spectrometry (ETV-APGD-AES) device. A "short-path" transmission architecture was developed by drastically minimizing the physical distance between the tungsten coil (W-coil) vapori...
Jin-Mei Wang, Rui-Peng Li, P. Zheng et al.· Analytical Methods· 0 citations