Nested-Loop Control of DC/DC Converter Twins via a Novel Per-Unit and Time–Angular Transformation

Sep 2026 · Electronics · 0 citations · 37 references

Abstract

The application of DC power electronics has expanded significantly across modern transmission and distribution systems, spanning medium-voltage direct current (MVDC) and high-voltage direct current (HVDC) networks, as well as low-power DC supplies for nanoscale applications, in which experimental validation remains indispensable for verifying system performance and control strategies. However, developing experimental platforms for high-power, high-voltage, or nanoscale DC systems is technically challenging and expensive and has not been adequately addressed in the existing literature. To overcome these limitations, this paper presents a per-unit-based experimental twin (Ex-Twin) framework for Buck converters implemented with a nested-loop control architecture. By transforming the converter dynamics from the time domain to an angular-domain representation, the proposed per-unit framework enables the development of dynamically equivalent experimental twins across a wide range of operating scales. The feasibility and effectiveness of the proposed Ex-Twin framework are validated through comprehensive electromagnetic (EMT) simulation studies and hardware experimental results, demonstrating its potential as a scalable and cost-effective platform for the development, testing, and validation of advanced DC power electronic systems. EMT simulations verify the cross-scale dynamic equivalence of the converter models over power ratings from 2 kW to 2 MW and voltage levels from 54 V to 54 kV, provided that the corresponding per-unit parameters and normalized disturbances are preserved. Under the investigated operating conditions, the systems achieved efficiencies of 95.3%, 96.7%, and 94.3% at 2 kW, 20 kW, and 2 MW, respectively, using both the real-scale and corresponding per-unit controllers. These results demonstrate consistent performance across the evaluated power scales. In addition, laboratory tests conducted on a 1 kW, 50 V Buck-converter platform validate the real-time implementation of both the real-scale and per-unit controllers under reference-voltage and load disturbances. An experimentally measured efficiency of 92.1% was achieved with both controllers, further demonstrating their consistent performance.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.