Skip to content
Open access

Early changes in CT-derived quantitative flow ratio after transcatheter aortic valve replacement: a serial coronary physiological assessment

Oct 2026 · Frontiers in Cardiovascular Medicine · Vol 13 · 0 citations · 23 references
Medicine

TL;DR

The findings suggest that coronary physiological assessment in severe aortic stenosis may be influenced by valve intervention and should be interpreted cautiously during the peri-TAVR period.

Abstract

Aims Transcatheter aortic valve replacement (TAVR) is an established treatment for severe aortic valve stenosis, but its effects on coronary physiology remain incompletely understood. CT-derived quantitative flow ratio (CT-QFR) enables non-invasive assessment of coronary physiology. This study aimed to investigate the early changes in CT-QFR following TAVR. Methods This retrospective study included consecutive patients with severe aortic stenosis who underwent coronary computed tomography angiography before and within 7 days after TAVR. CT-QFR was calculated for all analyzable coronary vessels. Longitudinal changes in CT-QFR were evaluated using linear mixed-effects models with patient identifier as a random effect. Results A total of 109 patients (324 coronary vessels) were analyzed. Plaque volume, plaque burden, and minimal lumen diameter remained unchanged after TAVR, whereas transvalvular pressure gradients decreased significantly. Overall, CT-QFR increased modestly following TAVR (β=0.018, P < 0.001). Significant increases were observed in the left anterior descending and right coronary arteries, whereas no significant change was detected in the left circumflex artery. Vessels with baseline %DS ≥50% demonstrated greater CT-QFR increases than those with less severe stenosis (interaction β=0.104, P < 0.001). Likewise, vessels with baseline CT-QFR <0.80 showed significantly larger post-TAVR increases than vessels with baseline CT-QFR ≥0.80 (interaction β=0.117, P < 0.001). Conclusion TAVR was associated with modest early increases in CT-QFR, particularly in vessels with greater anatomical stenosis or baseline physiological impairment. These findings suggest that coronary physiological assessment in severe aortic stenosis may be influenced by valve intervention and should be interpreted cautiously during the peri-TAVR period.

Read PDF

Similar papers

Open access Oct 2026

Five years of evidence: impact of aortic stenosis severity on angiography-derived QFR before and after TAVI

Transcatheter aortic valve implantation (TAVI) results in a significant reduction of transvalvular gradients, which may influence coronary hemodynamics. Whether the severity of aortic stenosis affects angiography-derived coronary physiology remains uncertain. We investigated the impact of baseline aortic stenosis...

E. Nela, S. Bargon, J. Schlueter et al. · 0 citations
Review Open access Nov 2026

Prognostic Value of Tissue Doppler Late Diastolic Velocity (TDI-a') in Patients with Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation.

Risk stratification after transcatheter aortic valve implantation (TAVI) in severe aortic stenosis (AS) remains suboptimal. Beyond valvular hemodynamics, a number of standard echocardiographic parameters of function are associated to outcome. Mitral annular late diastolic velocity (TDI-a') is proven to have prognostic...

A. Cecchetto, Roberta Bogoni, F. Zupa et al. · 0 citations
Meta-analysis Open access Oct 2026

Coronary microvascular dysfunction in patients undergoing transcatheter aortic valve implantation: A systematic review and meta-analysis

Background Coronary microvascular dysfunction (CMD) is a complication of severe aortic stenosis. Its prevalence after transcatheter aortic valve implantation (TAVI) and prognostic significance are understudied, as are the post-TAVI trajectories of microvascular indices. Aims The aims of this study were to determine the...

Maethas Panyawongkhanti, Peerawat Chintrakulchai, C. Tanking et al. · 0 citations
Open access Nov 2026

Development of a Quantitative Contrast CT-Based TAVR-Risk Score to Reliably Predict Deformation in Bicuspid Aortic Valves.

BACKGROUND Bicuspid aortic valve (BAV) calcification affects clinical outcomes by causing transcatheter heart valve (THV) deformation after transcatheter aortic valve replacement (TAVR). However, a computed tomography (CT)-based scoring system for grading BAV calcification severity and predicting THV deformation has no...

K. Suruga, V. Patel, H. Jilaihawi et al. · 1 citation
Open access Oct 2026

Influence of ascending aorta diameter on short- and long-term clinical outcomes after transcatheter aortic valve implantation for bicuspid aortic valve stenosis

Bicuspid aortic valve (BAV) stenosis has been associated with challenging anatomical features for transcatheter aortic valve implantation (TAVI). Ascending aorta dilatation is frequently observed in patients with BAV stenosis and its implications for TAVI outcomes remain undetermined. To assess short and l...

D. Giacoppo, H. Alvarez-Covarrubias, T. Pilgrim et al. · 0 citations
Open access Oct 2026

Extracellular volume by cardiac CT and the haemodynamic progression of aortic stenosis

The rate of aortic stenosis (AS) progression is a major determinant of myocardial damage and adverse clinical outcomes. Sustained pressure overload drives diffuse myocardial fibrosis, which can be quantified non-invasively by computed tomography (CT)-derived extracellular volume (ECV). However, data on ECV change...

A. Lobo, C. Castro, M. Almeida et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.