Skip to content

A Mechanomyography-Based Integrated Sensing-Stimulation System for Fatigue-Aware Neuromuscular Therapy

Oct 2026 · 0 citations · 36 references
Computer Science

TL;DR

Findings support MMG as a physiologically meaningful and stimulation-compatible modality for fatigue-aware closed-loop neuromuscular stimulation.

Abstract

Muscle fatigue limits the effectiveness of functional electrical stimulation (FES), yet fatigue monitoring during active stimulation remains challenging because electromyography (EMG) is severely contaminated by stimulation artifacts. To address this issue, this study proposes an integrated mechanomyography-based sensing framework (MMG-FES) for artifact-resistant fatigue monitoring during stimulation. Fatigue states were first characterized during voluntary movement using established EMG spectral indicators, including median frequency (MF) and mean power frequency (MPF), and then linked to MMG-derived features, including high-frequency energy ratio (HFER) and spectral bandwidth (BW), for fatigue recognition under stimulation conditions. Experimental results showed consistent fatigue-related trends, with EMG spectral features decreasing and MMG features exhibiting coordinated spectral redistribution across repeated contractions. Using these features, the proposed framework achieved fatigue-state recognition accuracies of 0.93 and 0.96 with logistic regression and random forest, respectively. These findings support MMG as a physiologically meaningful and stimulation-compatible modality for fatigue-aware closed-loop neuromuscular stimulation.

View source

Similar papers

#human-computer interacti... Preprint Oct 2026

A Co-Located MMG-FES Wearable Interface for Action-Updated State-Gated Stimulation

Functional electrical stimulation (FES) assists movement, but fixed schedules cannot track how a repeatedly activated muscle changes, and surface electromyography (EMG) near the stimulation electrodes is often obscured by artifacts. Prior work recorded mechanomyography (MMG) passively during closed-loop FES cycling and...

Cong-Wei Liu, Xiao Jin, Zhen-Hua Yu · 0 citations
Open access Oct 2026

A Standardized Methodology for EMG-Based Fatigue Assessment during Electrical Muscle Stimulation

Abstract This study presents a methodological framework for standardized electromyographic (EMG) fatigue assessment during electrical muscle stimulation (EMS), with a focus on M. biceps brachii. Based on existing literature, a protocol was developed and iteratively optimized through controlled trials. The approach addr...

Katja Uhrhan, H. Witte · 0 citations
Open access Oct 2026

Wearable Surface Electromyography Sensor-Based Assessment of Intermuscular Time–Frequency Coherence Following Neuromuscular Electrical Stimulation Combined with Loaded Back Squats During Tennis Forehand Strokes

Objective: This study used synchronized wearable surface electromyography sensors and high-speed video to compare post-intervention intermuscular time–frequency coherence (TFC) among three pre-competition activation conditions during the tennis forehand drive and forehand slice. Methods: Thirty tennis players were rand...

Yi-Fei Jiang, Wei-Hao Jiang · 0 citations
Open access 2026

XGBoost-Based Classification of Electromyography Signal for Muscle Contraction and Relaxation: A Correlation-Guided Feature Analysis Approach

Analyzing electromyography (EMG) signals has become one of the important methods in biomedical engineering for researching neuromuscular function that is non-invasive, with applications such as robotic rehabilitation, prosthetics, and human-machine interface design. Despite significant improvements in EMG pattern recog...

Nashreen Hilman, N. Izni, Mohd Azizi Abdul Rahman et al. · 0 citations
Open access Oct 2026

A Performance Comparison of Forcemyography and Electromyography in Muscle Force Estimation for Human–Machine Interfaces

Highlights What are the main findings? FMG achieved better mean force-estimation metrics than EMG-RMS, with significant advantages in selected comparisons, particularly during rapid isometric contractions. Subject-specific sigmoidal models estimated muscle force from FMG and EMG-RMS on held-out contractions. What are t...

J. Centracchio, S. Parlato, E. Andreozzi et al. · 0 citations
Review Open access Sep 2026

Therapeutic uses of surface electromyography for rehabilitation: An emerging tool across clinical applications.

Surface electromyography (EMG) is a noninvasive technology that detects voluntary muscle activation and has emerged as a valuable tool for neuromuscular assessment and rehabilitation. By using surface electrodes placed over targeted muscle groups, EMG enables the detection of muscle activity without the discomfort asso...

Stephanie H. Vu, J. Lutgens, Kathrine R. Manolopoulos et al. · 0 citations

Related blog posts

Microsoft Research Blog Nov 5, 2026

Formally verifying agent-written full-stack web apps with PDD Kit

AI agents can generate code at a scale that’s hard for humans to review line-by-line. PDD Kit helps ensure the code is doing what the developer intended by creating formal specifications and testing against them. It converts developer intent into a Verus specification, proves AI-generated code meets it for every input, and uses tests where proofs aren't practical. Developers review intent, not every line. The post Formally verifying agent-written full-stack web apps with PDD Kit appeared first o…

MIT News · Artificial Intelligence Oct 28, 2026

Making machines that can listen

Professor Paris Smaragdis develops computers with superhuman hearing for applications like speech recognition, music understanding, and environmental monitoring.

MIT News · Artificial Intelligence Oct 23, 2026

Reinforcing the value of human understanding at MIT

During the School of Humanities, Arts, and Social Sciences’ 75th Anniversary Symposium, President Sally Kornbluth said “MIT has never needed your particular insight and guidance more than we do now.”

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.