A Low-Cost Monocular Video-Based Framework for Bilateral Plantar Load Estimation During Treadmill Walking

Oct 2026 · Italian National Conference on Sensors · 0 citations · 29 references

Abstract

Plantar load is an important biomechanical measure in gait analysis, rehabilitation assessment, and human movement evaluation. However, conventional measurement systems, including instrumented insoles and laboratory-based force measurement devices, rely on dedicated sensing hardware and may limit the accessibility of continuous gait monitoring. This study proposes a low-cost, monocular video-based framework for estimating bilateral plantar loads from pose-derived biomechanical features. As an initial application setting, we focused on treadmill walking, where a stationary camera can capture repeated body motion under consistent recording conditions, allowing the relationship between video-derived biomechanical features and plantar loading to be investigated before extending the framework to more variable environments. Video and reference plantar-load data from 14 healthy adults during treadmill walking at 3 km/h were temporally aligned, yielding 50,464 frame-level observations. Body landmarks estimated using MediaPipe Pose were used to construct posture-related, motion-related, and short-term temporal features. Four machine-learning regressors were evaluated, with fold-specific Top-60 feature selection applied to the morphology-excluded feature configuration. ExtraTrees achieved the highest mean performance under blocked temporal five-fold cross-validation, with R2 values of 0.762 ± 0.068 and 0.772 ± 0.073 for the left- and right-foot loads, respectively. Feature-group ablation showed that removing three static morphology variables had only a small effect on blocked-validation performance. Under zero-shot leave-one-subject-out validation, the corresponding mean R2 values were −0.252 ± 0.592 and −0.180 ± 0.573, indicating limited generalization to previously unseen participants. Using the initial 30 s of reference-load data for subject-specific supervised calibration improved prediction performance on the matched post-calibration interval. Regularized temporal, scale, and offset calibration increased the mean R2 values from −0.233 to 0.358 for the left-foot target and from −0.141 to 0.444 for the right-foot target. These findings demonstrate the potential of monocular video-derived biomechanical features for bilateral plantar-load estimation during controlled treadmill walking. Short supervised calibration improved average prediction performance for unseen participants, enabling subsequent video-based estimation without continuous wearable-sensor measurements.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.