Jul 2026· Applied and Computational Engineering· Vol 243, pp. 64-74· 0 citations
Abstract
In practical power systems, transformers are continuously involved in voltage conversion and electrical-energy transmission, so once abnormal operating conditions appear inside the equipment, the influence may gradually spread to the stability of the entire grid. Because early-stage transformer faults are usually weak and not easy to observe directly from conventional electrical quantities, this paper investigates a fault-monitoring method based on current-signal trajectories and discusses its application to transformer operating-state analysis. In the proposed approach, the primary-side and secondary-side current signals are taken as the basic data source, and the corresponding Lissajous trajectories are then constructed under different operating conditions. Instead of analyzing only waveform amplitude or phase separately, the method converts the current relationship into geometric trajectory characteristics, making the variation process easier to observe visually. To examine whether the method remains effective under different fault levels, a transformer equivalent-circuit model was built in Multisim, and several abnormal operating conditions were reproduced by changing equivalent impedance parameters and related electrical quantities. During the simulation analysis, several ellipse-related quantities were extracted from the generated trajectories, mainly including ellipse area together with the ratio between the major axis and minor axis. These geometric quantities were then compared under healthy and faulty operating conditions. The obtained results show that even under relatively weak parameter disturbances, such as ±3% variations, the trajectory shape had already changed slightly compared with the normal state, and the corresponding feature deviation approached about 5% in some simulation cases. After the disturbance level continued to increase, especially when the parameter variation reached around ±30%, the deformation of the ellipse became much more obvious, while part of the geometric feature variation exceeded 32%. From the overall simulation results, it can be seen that the trajectory characteristics still maintain visible differences under different transformer operating conditions, including relatively weak abnormal states appearing at an early stage. Compared with directly using conventional electrical signal quantities for analysis, the proposed method represents operating-state variation through geometric trajectories, so some small parameter changes can be reflected more intuitively. The study therefore suggests that current-signal trajectory analysis may provide another possible way for transformer online monitoring and operating-condition evaluation in practical engineering applications.
Transformer degradation is often accompanied by changes in electrical characteristics. Such changes may originate from insulation defects, winding abnormalities, or local dielectric damage. Detecting these variations at an early stage remains a challenge for condition monitoring. In this work, primary-side and secondar...
Zihao Zhong· Applied and Computational En...· 0 citations
As a critical component of power systems, the operational status of power transformers directly affects the safety and reliability of the power grid. Addressing the challenge that traditional methods struggle to achieve online monitoring of winding deformation faults, this paper proposes a novel method for online detec...
Lai-Hong Wei· European Conference on Elect...· 0 citations
Strong noise in high-voltage transformer environments can easily overwhelm weak fault signals during the switching control of simulated fault resistance networks. This interference hinders the accurate identification of fault types and levels, ultimately compromising the stability and accuracy of the switching process....
Wei-Ping Wu, Tie-Gang Yang· Journal of Physics, Conferen...· 0 citations
Internal temperature monitoring is an important approach for assessing the operating condition of power transformers. Temperature-rise characteristics not only indicate faults such as inter-turn short circuits but also indirectly reflect the diffusion and transport behaviors of characteristic dissolved gases within the...
Zi-Fan Zhao, Shan Yu, Shi-Man Lin et al.· Energies· 0 citations
Existing EMTR methods typically adopt passive location schemes that rely on transient signals generated by faults. When faults occur at a low inception angle, the resulting traveling-wave signals are typically weak and suffer from poor detectability. Active pulse injection provides controllable excitation and improves...
In recent years, high penetrations of inverter-based resources are posing significant challenges to the medium-voltage networks, in which protection schemes based on high fault currents and unidirectional power flow may not perform as expected. This paper proposes a dynamic fault-detection and relay-coordination scheme...
Muhammad Abdul Rauf, Munira Batool, I. Madni· Energies· 0 citations