A Method for Diagnosing Lower Transformer Faults Based on Current Signal Trajectories and Its Implementation

Jul 2026 · Applied and Computational Engineering · Vol 243, pp. 64-74 · 0 citations

Abstract

In practical power systems, transformers are continuously involved in voltage conversion and electrical-energy transmission, so once abnormal operating conditions appear inside the equipment, the influence may gradually spread to the stability of the entire grid. Because early-stage transformer faults are usually weak and not easy to observe directly from conventional electrical quantities, this paper investigates a fault-monitoring method based on current-signal trajectories and discusses its application to transformer operating-state analysis. In the proposed approach, the primary-side and secondary-side current signals are taken as the basic data source, and the corresponding Lissajous trajectories are then constructed under different operating conditions. Instead of analyzing only waveform amplitude or phase separately, the method converts the current relationship into geometric trajectory characteristics, making the variation process easier to observe visually. To examine whether the method remains effective under different fault levels, a transformer equivalent-circuit model was built in Multisim, and several abnormal operating conditions were reproduced by changing equivalent impedance parameters and related electrical quantities. During the simulation analysis, several ellipse-related quantities were extracted from the generated trajectories, mainly including ellipse area together with the ratio between the major axis and minor axis. These geometric quantities were then compared under healthy and faulty operating conditions. The obtained results show that even under relatively weak parameter disturbances, such as ±3% variations, the trajectory shape had already changed slightly compared with the normal state, and the corresponding feature deviation approached about 5% in some simulation cases. After the disturbance level continued to increase, especially when the parameter variation reached around ±30%, the deformation of the ellipse became much more obvious, while part of the geometric feature variation exceeded 32%. From the overall simulation results, it can be seen that the trajectory characteristics still maintain visible differences under different transformer operating conditions, including relatively weak abnormal states appearing at an early stage. Compared with directly using conventional electrical signal quantities for analysis, the proposed method represents operating-state variation through geometric trajectories, so some small parameter changes can be reflected more intuitively. The study therefore suggests that current-signal trajectory analysis may provide another possible way for transformer online monitoring and operating-condition evaluation in practical engineering applications.

Read PDF

Similar papers

Open access Aug 2026

A Method for Diagnosing Transformer Faults under Online Voltage Signals

Transformer degradation is often accompanied by changes in electrical characteristics. Such changes may originate from insulation defects, winding abnormalities, or local dielectric damage. Detecting these variations at an early stage remains a challenge for condition monitoring. In this work, primary-side and secondar...

Zihao Zhong · 0 citations
Sep 2026

A study on the diagnosis of power transformer winding faults considering power and voltage characteristics

As a critical component of power systems, the operational status of power transformers directly affects the safety and reliability of the power grid. Addressing the challenge that traditional methods struggle to achieve online monitoring of winding deformation faults, this paper proposes a novel method for online detec...

Lai-Hong Wei · 0 citations
Conference Open access Aug 2026

Automatic switching control of transformer simulated fault resistance network based on high-voltage integrated signal enhancement algorithm

Strong noise in high-voltage transformer environments can easily overwhelm weak fault signals during the switching control of simulated fault resistance networks. This interference hinders the accurate identification of fault types and levels, ultimately compromising the stability and accuracy of the switching process....

Wei-Ping Wu, Tie-Gang Yang · 0 citations
#diffusion models Open access Sep 2026

Thermal–Fluid Characteristics of Transformer Winding Inter-Turn Short Circuits and Their Application to Fault Localization

Internal temperature monitoring is an important approach for assessing the operating condition of power transformers. Temperature-rise characteristics not only indicate faults such as inter-turn short circuits but also indirectly reflect the diffusion and transport behaviors of characteristic dissolved gases within the...

Zi-Fan Zhao, Shan Yu, Shi-Man Lin et al. · 0 citations
Open access Aug 2026

Electromagnetic Time-Reversal Fault Location Using Active Pulse Injection

Existing EMTR methods typically adopt passive location schemes that rely on transient signals generated by faults. When faults occur at a low inception angle, the resulting traveling-wave signals are typically weak and suffer from poor detectability. Active pulse injection provides controllable excitation and improves...

Yu-Chu Lu, Wei Dong, Cheng-Xuan Tang et al. · 0 citations
Open access Aug 2026

Dynamic Fault Detection and Protection Strategies for Medium-Voltage Networks Supplied by Grid-Forming Inverter Sources

In recent years, high penetrations of inverter-based resources are posing significant challenges to the medium-voltage networks, in which protection schemes based on high fault currents and unidirectional power flow may not perform as expected. This paper proposes a dynamic fault-detection and relay-coordination scheme...

Muhammad Abdul Rauf, Munira Batool, I. Madni · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.