Static and cyclic response of novel gravity base foundations for offshore and onshore wind turbines
Abstract
The increasing need for renewable energy has resulted in the swift proliferation of wind power, both onshore and offshore. In order for the adequate development of off shore wind industry, it is necessary to resolve some uncertainties with regards to foundation employed for these structures. With wind turbines becoming larger and more powerful, the need for strong, stable, and efficient foundation systems is more critical than ever. Till recently monopiles are widely used in case of offshore wind structures across the world but due to surge in capacity of offshore wind production across the world, there needs an efficient and alternate foundation systems. The alternative foundations such as gravity-based foundations (GBFs) basically resists large compressive loads apart from cyclic loads subjected due to wind and wave actions. These foundations are placed at shallow depth having sound bearing stratum and having larger width of foundations. The present study focuses on the static compressive performance of newly designed, prefabricated GBFs models with and without fins or ribs to enhance the load bearing capacity. A series of laboratory tests were performed on model gravity based foundations embedded in silica sand with uniformity coefficient and coefficient of curvature are 1.53 and 0.94 respectively signifying poorly graded sand as per Indian Standard Classification of Soils. An attempt is also made to vary the rib shape of triangular and trapezoidal; number of ribs are varied as 4 and 8, and thickness is varied as 6 mm, 8 mm and 10 mm respectively. It was found that the ultimate bearing capacity of conventional GBFs is 244.21 kN/m2, where as the ultimate bearing capacity of triangular ribs of 8 No’s for 10 mm rib thickness was found to be 295.01 kN/m2 with a rib efficiency of 1.21 and also with respect to trapezoidal ribs of 8 No’s for 10 mm rib thickness was found to be 343.54 kN/m2 with a rib efficiency of 1.41, so it can concluded that ribbed GBFs enhance load bearing capacity and efficient material distribution. In the present study a series of cyclic load tests were conducted on conventional and triangular and trapezoidal ribbed pre-fabricated GBFs and evaluated dynamic parameters such as coefficient of elastic uniform compression(Cu) and found that Cu was found to be 1.89 × 105 kN/m3 in case of conventional GBFs where as in case of triangular ribs with 8 No’s it varies from 1.69×105 kN/m3 with 6 mm rib thickness to 3.40×105 kN/m3 with 10 mm rib thickness and in case of trapezoidal ribs with 8 No’s it varies from 2.22×105 kN/m3 with 6 mm rib thickness to 4.02×105 kN/m3 with 10 mm rib thickness. These findings indicate that the inclusion of ribs with enhanced thickness markedly enhances the ultimate bearing capacity and stiffness of GBFs. The experimental findings support the use of ribbed GBFs in both onshore and offshore wind farms, offering a practical solution for foundation-related challenges. This research bridges the gap between theoretical concepts and practical applications, contributing valuable insights toward the future development of cost-effective and high performing wind turbine foundation systems.