Skip to content

A unified signal-quality assessment framework for synchronized electro-intravascular encephalography and scalp electroencephalography.

Sep 2026 · Journal of NeuroInterventional Surgery · pp. jnis-2026-025329 · 0 citations · 28 references
Medicine

TL;DR

This framework enables interpretable and reproducible evaluation of EiEG signal quality and showed high physiological concordance with scalp EEG together with higher spectral fidelity and greater across-bout consistency.

Abstract

Background

Neurointerventional electrophysiology enables minimally invasive access to near-cortical signals without craniotomy. However, a standardized and interpretable signal-quality evaluation framework for electro-intravascular encephalography (EiEG) is lacking, limiting reproducible reporting and principled comparison with conventional scalp electroencephalography (EEG).

Methods

We proposed a framework quantifying physiological concordance, spectral fidelity, and robustness, and validated it in an ovine EiEG model using a stent-mounted electrode deployed in the superior sagittal sinus over the motor cortex. EiEG and spatially corresponding scalp EEG were synchronously recorded across four repeated 5 min bouts using shared hardware and matched preprocessing.

Results

Using the proposed framework in this preparation, we evaluated physiological concordance, spectral fidelity (signal-to-noise ratio (SNR) index), and robustness in simultaneous EiEG and scalp EEG recordings. Concordance was high (Spearman's ρ>0.94). Under the unified SNR definition, the framework quantified overall linear SNR ratios of 2.04 vs Cz and 1.84 vs C1 over 0.5-40 Hz. Across four repeated 5 min recording bouts, EiEG showed greater consistency than scalp EEG, with lower overall-band across-bout coefficient of variation (CV: 0.8% vs 29.8% for Cz and 6.7% for C1) and lower mean absolute relative deviation from bout 1 (1.5% vs 23.6% and 5.4%, respectively). No acute procedure-related complications were observed.

Conclusions

This framework enables interpretable and reproducible evaluation of EiEG signal quality. When applied to this preparation under synchronized recording, EiEG showed high physiological concordance with scalp EEG together with higher spectral fidelity and greater across-bout consistency.

View source

Similar papers

Sep 2026

Human Recorded Signal Properties of Endovascular EEG Compared to Conventional Scalp EEG.

OBJECTIVE Endovascular EEG (eEEG) has emerged as a brain monitoring technique that offers a balance between signal fidelity and invasiveness. Endovascular electrodes match subdural recordings in bandwidth and signal-to-noise ratio in animal studies, however, their signal properties remain sparsely quantified in humans....

Luis Torres Mailleux, Kota Araki, Modar Hassan et al. · 0 citations
Open access Sep 2026

Measuring motor intent for BCI control–A comparative analysis of signal quality of simultaneously recorded vECoG and scalp EEG

Objective. Stent-electrode arrays enable endovascular brain–computer interfaces (BCI) by recording cortical neural activity from within the superior sagittal sinus and have recently been evaluated in an early feasibility clinical trial in the United States (ClinicalTrials.gov: NCT05035823). For a BCI to be viable, the...

N. Chetty, James Bennett, Hunter R. Schone et al. · 0 citations
Review Aug 2026

Virtual iEEG from Scalp EEG: Charting the Landscape of Source Imaging, Intracranial Inference and Reconstruction

Intracranial electroencephalography (iEEG) provides temporally precise and spatially specific access to neural activity from focal and deep brain regions, but its invasiveness and restricted anatomical coverage limit routine use. These constraints have motivated scalp-to-intracranial inference, termed virtual iEEG when...

Dong-Yi He, Xiang-Kai Wang, Hong-Jie Yan et al. · 0 citations
Review Open access Oct 2026

Neurovascular coupling in simultaneous EEG-fNIRS studies: A scoping review of analytical frameworks and clinical applications.

Simultaneous electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) have been used across cognitive and physiological states and in diverse clinical populations. However, the interpretation of cross-modal coupling remains difficult because findings from different analytical frameworks, populatio...

Wsu Yu, R. Yuvaraj, S. Perrey et al. · 0 citations
Review Open access Oct 2026

Applications of functional ultrasound brain-computer interfaces in neurological diseases: research progress based on neurovascular coupling

Brain-computer interfaces (BCIs) bypass peripheral nerves and muscles to establish direct information pathways between the brain and external devices, providing novel approaches for motor function reconstruction, communication assistance, and neurorehabilitation in patients with neurological disorders. However, convent...

Cheng-Shan Zhang · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.