Single-lead (Lead I) ECG provides HRV information comparable to Lead II for time-domain metrics, supporting the utility of wearable single-lead ECG for RRI estimation and time-domain HRV monitoring; however, systematic differences in R-wave morphology warrant lead-specific calibration of automated detection algorithms.
Abstract
Background: Wearable electrocardiogram (ECG) devices capable of recording a single-lead signal—typically Lead I—have proliferated rapidly, enabling long-term ambulatory cardiac monitoring outside clinical settings. However, the extent to which Lead I-derived heart rate variability (HRV) metrics are concordant with those obtained from the clinical gold standards—12-lead ECG and 3-channel Holter monitoring—remains incompletely characterised. Methods: We analysed RR-interval series extracted from (i) the PTB-XL large-scale publicly available 12-lead ECG dataset (n = 18,869 patients; 100 Hz, 10 s recordings) and (ii) ambulatory 3-channel Holter ECG recordings (Suzuken Pico303) from four participants (two elderly adults and two young adults). Pan–Tompkins R-wave detection was applied uniformly. Time-domain (SDNN, RMSSD, and pNN50), Poincaré (SD1 and SD2), and Bland–Altman agreement metrics were computed for Lead I versus Lead II comparisons. Results: Analysis of 300 PTB-XL records (a contiguous pilot subset: records 00040–00350) stratified by diagnostic superclass revealed strong Lead I–Lead II RRI concordance for normal ECGs (NORM: r = 0.844, ICC(2,1) = 0.841, mean bias = −1.4 ms, 95% LoA [−52.4, +49.7] ms; n = 179 records) and progressively lower agreement in pathological categories (MI: r = 0.659, ICC = 0.663; CD: r = 0.433, ICC = 0.484; HYP: r = 0.556, ICC = 0.574; STTC: r = 0.635, ICC = 0.634). Holter Pico303 recordings demonstrated significant inter-individual variability; SDNN ranged from 37.0 ms (elderly male) to 80.8 ms (elderly female) and 80.4 ms (young male), while RMSSD ranged from 27.0 to 68.0 ms. R-wave amplitude was systematically higher in Lead II (0.734 ± 0.413 mV) than Lead I (0.667 ± 0.339 mV) across the 300-record cohort (overall mean). Conclusions: Single-lead (Lead I) ECG provides HRV information comparable to Lead II for time-domain metrics, supporting the utility of wearable single-lead ECG for RRI estimation and time-domain HRV monitoring; however, systematic differences in R-wave morphology warrant lead-specific calibration of automated detection algorithms.
Background Autonomic regulation and the heart's electrical activity are both central to normal cardiac function, yet there is currently no direct way to capture the interaction between them from a standard ECG. This paper introduces the Autonomic–Ventricular Coherence Index (AVCI), a single-lead ECG method that measure...
Jayasree R, C. G· Frontiers in Digital Health· 0 citations
Ambulatory Holter electrocardiogram (ECG) monitoring is increasingly used in ambulatory elderly populations; however, age-related physiological and mechanical factors substantially increase susceptibility to motion-induced signal artifacts, limiting reliable heart rate (HR) variability (HRV) analysis. This study aims t...
Naoya Morikawa, Emi Yuda· Journal of Experimental and...· 0 citations
Aims: Structural heart disease (SHD) often remains undetected until symptoms develop. Portable 1-lead ECG devices return an automated rhythm-based interpretation, but whether AI-ECG adds diagnostic value beyond this interpretation is unknown. We prospectively evaluated a noise-adapted 1-lead AI-ECG algorithm for detect...
A. Aminorroaya, S. Shankar, Mariam Khan et al.· medRxiv· 0 citations
Wearable single-lead electrocardiogram (ECG) devices are increasingly used for out-of-clinic rhythm monitoring, but the rigour with which their signal-processing pipelines are validated varies widely across the literature, with most published reports relying on either a single clinical comparison or a single algorithmi...
J. Vrdoljak, Dora Aletta Racz· Italian National Conference...· 0 citations
Use for heart rate, QRS timing, and visual rhythm review in controlled recordings, but not standalone diagnosis is supported, as well as morphology, which was generally close to the reference.
S. J. White, Ekenedirichukwu N. Obianom, Fan Feng et al.· 0 citations