B-365 Breaking Throughput Barriers: Automated Vitamin D Testing on the Roche Cobas i601 LC-MS/MS in a Tertiary Hospital Laboratory

Oct 2026 · Clinical Chemistry · 0 citations

Abstract

Measurement of 25-hydroxyvitamin D (25-OH-D), including 25-OH-D2 and 25-OH-D3, is essential for assessing vitamin D status in clinical practice. Liquid chromatography–tandem mass spectrometry (LC-MS/MS) is considered the reference method due to its superior analytical specificity and ability to distinguish vitamin D metabolites. However, conventional LC-MS/MS platforms require extensive manual specimen preparation, specialised expertise, and significant hands-on time, limiting scalability in routine clinical laboratories. The Roche Cobas i601 represents a fully automated clinical LC-MS/MS system designed to streamline workflows while maintaining reference-method performance. Our study evaluated the analytical performance of the Roche i601 LC-MS/MS system for quantification of total 25-OH-D, 25-OH-D2, and 25-OH-D3 in human serum and its suitability for high-throughput testing in a tertiary hospital laboratory. Analytical performance evaluation was conducted on two separate LC streams following our laboratory’s verification protocols which included studies on imprecision, linearity, carryover, limits of detection and quantification. Method correlation was performed against our laboratory’s established LC-MS/MS method (on Agilent UHPLC 1290 - Sciex QTrap 5500 LC-MS/MS), using 108 patient serum specimens for total 25-OH-D and 25-OH-D3, and 63 specimens for 25-OH-D2. Agreement was evaluated using Passing-Bablok regression, Spearman correlation, and Bland-Altman analysis. Matrix effects were evaluated using 10 patient serum pools spiked with 25-OH-D2 and D3 at 4 concentrations. Matrix effect was assessed by calculating percent recovery relative to expected concentrations, summarised as mean recovery and CV% to evaluate ion suppression or enhancement. Within-run and total imprecision CVs for total 25-OH-D, and 25-OH-D3 on the Roche i601 ranged from 1.9% to 3.8%. The assays demonstrated linearity across the analytical measurement from 2.0 to 150 ng/mL. The LODs and LOQs were verified at 2.0 ng/mL for 25-OH-D2, and 25-OH-D3. No significant carryover was observed for both LC channels. Method correlation with in-house method demonstrated good agreement with in-house assay. Bland-Altman analysis showed a mean positive bias of +0.97% (95% CI: 2.02 to 4.84%), +3.57% (95% CI: 2.23 to 4.92%) for 25-OH-D2, and 25-OH-D3 analytes. Passing-Bablok regression analysis demonstrated regression equations of [i601] = 1.08 × [In-house] - 0.34 (R² = 0.97) for 25-OH-D2 and [i601] = 1.09 × [In-house] - 1.07 (R² = 0.98) for 25-OH-D3. Matrix effect studies demonstrated acceptable recovery across tested concentrations, with recoveries ranging 86 to 113% for both 25-OH-D2 and 25-OH-D3, confirming effective compensation for ion suppression/enhancement through use of isotopically labelled internal standards. These findings indicate minimal clinically significant matrix interference and reliable quantification across the analytical measuring range. The Roche i601 automated LC-MS/MS system demonstrated excellent analytical performance for measurement of total 25-OH-vitamin D, and 25-OH-D3, with high precision, strong agreement with our established LC-MS/MS method, and robust resistance to matrix effects. The fully automated workflow significantly reduces manual intervention while maintaining reference-grade analytical quality. Importantly, the system supports high-throughput testing with improved operational efficiency, making it well suited for implementation in high-workload tertiary hospital laboratories. This platform represents a significant advancement in clinical LC-MS/MS automation, enabling broader implementation of high-specificity Vitamin D testing in routine clinical laboratories while improving efficiency, scalabil

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.