Aug 2026· Preventif : Jurnal Kesehatan Masyarakat· Vol 17, pp. 46-64· 0 citations· 18 references
TL;DR
Although the building is considered safe for use, several deficiencies were identified, particularly in active fire protection systems, life-saving facilities, and site completeness, and Improvements in fire protection facilities, evacuation routes, and regular maintenance are recommended to enhance overall fire safety.
Abstract
Fire incidents in hospitals pose serious risks to patient safety, medical personnel, and the continuity of health services. Therefore, the readiness of fire protection systems is critical to enhancing safety in healthcare facilities. This study aims to evaluate the readiness of the fire protection system in the Pediatric Inpatient and Surgical Building of Ngudi Waluyo Wlingi Hospital, using the Building Safety System Reliability Value assessment method based on the Ministry of Public Works' Fire Protection Technical Guidelines. The assessment covers four main components: site equipment, life-saving facilities, active fire protection systems, and passive fire protection systems. Data were collected through direct observation, field measurements, and document review. The results showed that the building achieved an score of 79.23%, which falls within the sufficient category. Although the building is considered safe for use, several deficiencies were identified, particularly in active fire protection systems, life-saving facilities, and site completeness. Improvements in fire protection facilities, evacuation routes, and regular maintenance are recommended to enhance overall fire safety.
The short communication highlights the importance of fire prevention systems, emergency evacuation plans, and overall strategies and underscores the importance of educating both staff and patients about fire safety procedures.
A. Raut, Yugeshwari R. Tiwade, Shivani Shahu et al.· Medical Journal of Dr. D.Y....· 0 citations
Fire safety in buildings is often addressed through separate technical provisions such as fire detection, suppression, compartmentation, structural protection and means of escape. While these measures are essential, their effectiveness is also influenced by architectural decisions concerning building configuration, spa...
George Emetu, M. Zango, R. Martins· Knowledge Web Multidisciplin...· 0 citations
Operating-room fires, though rare, present unique risks to patient safety, staff health, and institutional resilience. Korean regulations (Medical Service Act, Framework Act on Fire Services, and Occupational Safety and Health Act) emphasize fire prevention and immediate response but lack systematic guidance for post-f...
Y. Choi, Sang Hun Kim· Anesthesia and Pain Medicine· 0 citations
Fire prevention infrastructure constitutes a critical component of safety governance in tertiary
institutions, particularly in Nigeria where rapid campus expansion, aging buildings, and weak
regulatory enforcement heighten vulnerability to fire outbreaks. This study aimed to assess the
availability of fire preventio...
Iribom Andesati Kurutsi· International Journal of Eng...· 0 citations
Access to adequate fire safety remains a significant challenge for many mixed-use buildings in
Kaduna, Nigeria, where systems are often compromised by generator-dependent power, informal
retail layouts, and low municipal water pressure. This study evaluates the integration of fire safety
strategies in such buildings to...
Yunusa Bohnum Ayuba· International Journal of Eng...· 0 citations
Market fire disasters in Nigeria continue to pose serious risks to lives, property, and
economic stability, largely due to weak safety infrastructure, poor enforcement of building
codes, and low user preparedness. The Modern Market in Karu, Abuja, exemplifies these
vulnerabilities, where inadequate escape routes, absen...
Elijah Akoshi Danfulani· International Journal of Eng...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.