Skip to content
Open access

Effect of Connection Geometry and Cantilever Length on the Mechanical Behavior of Ti6Al4V and PEEK Bar-Supported Implant Prostheses with Angled Abutments

Sep 2026 · Journal of Functional Biomaterials · Vol 17, pp. 458 · 0 citations · 46 references
Medicine

TL;DR

Findings indicate that cantilever length and connection geometry are critical parameters in designing full-arch implant prostheses and the use of PEEK as a bar material should be interpreted with caution under extended-cantilever conditions.

Abstract

Angled abutments and cantilever extensions in bar-supported full-arch implant prostheses may generate bending moments and localized stress concentrations within prosthetic components and peri-implant bone. Implant-supported rehabilitation becomes biomechanically more demanding in completely edentulous patients with posterior bone resorption. Therefore, understanding how connection geometry, cantilever length, and framework material influence prosthetic design is important. In this study, a three-dimensional mandibular model generated from CT data was used to compare conventional and spherical abutment–bar connection designs in All-on-Four prostheses with 30° angled posterior abutments. Cantilever lengths of 8, 10, and 12 mm were evaluated, and Ti6Al4V Grade 5 and PEEK were assigned as alternative bar prosthesis materials. Finite element analyses were performed in ANSYS Workbench, and von Mises stress distributions were evaluated in the bar prosthesis, prosthetic screws, abutments, implants, and surrounding cortical and trabecular bone. The results showed that increasing cantilever length increased stress levels in prosthetic components and bone tissues. The spherical connection design generally reduced stresses in the most critical distal components compared with the conventional design; however, this reduction was not uniform for all components, particularly in the PEEK models. The highest stress value was observed in the posterior angled abutment of the PC-12 model with a PEEK bar prosthesis (1592.2 MPa). Among the implant components, the lowest stress was observed in the anterior implant of the TS-8 model (27.99 MPa). In contrast, the lowest bone stress was recorded in the anterior trabecular bone capsule of the PC-8 model. These findings indicate that cantilever length and connection geometry are critical parameters in designing full-arch implant prostheses. At the same time, the use of PEEK as a bar material should be interpreted with caution under extended-cantilever conditions.

Read PDF

Similar papers

Open access Sep 2026

Biomechanical impact of anterior cantilever length on subperiosteal implants with different materials and configurations.

PURPOSE The aim of this study was to evaluate the influence of anterior cantilever length on stress distribution in subperiosteal implants (SI) fabricated from titanium and 60% carbon fiber-reinforced polyetheretherketone (PEEK) with one-piece and two-piece configurations using finite element analysis. MATERIALS AND...

Bersu Bedirhandede, Beyza Güney, Dilan Gizem Doğan et al. · 0 citations
Open access Oct 2026

Biomechanical assessment of titanium, zirconia, and polyetheretherketone abutments under functional loads: A finite element study.

Abutment material was found to play a critical role in the biomechanical performance of implant-supported restorations, affecting stress distribution within the implant system under functional loading.

Khaled Omran Ben Khalil, Simge Dagistan, Sinan Köse et al. · 0 citations
Open access Sep 2026

A Comparative Finite Element Analysis of Thread Geometry, Loading Direction, and Implant Material on Stress Distribution and Deformation in Dental Implants

Background/Objectives: This study evaluates the effects of axial and inclined loading on dental implants modeled with different material properties, thread geometries, and micro-thread configurations to compare their relative effects on stress and deformation behavior in cortical and cancellous bone. Methods: Five impl...

Priyanshu Roy, S. A. Abdul Khader, L. Puzhankara et al. · 0 citations
Open access Sep 2026

The effect of implant level in single six-support bridge-like prosthesis designs on the stress-strain state of structural elements based on three-dimensional mathematical modeling

Objective. To evaluate the stress-strain state of bone tissue supported by six dental implants under various types of occlusal loading by finite element analysis. Materials and methods. A three-dimensional finite element model of the mandibular segment with six implants and a fixed bridge prosthesis was developed. The...

S. Serebryanyy, A. Muraev, K. Salekh et al. · 0 citations
Open access Nov 2026

Clinical and Finite Element Evaluation of Fixed Implant Prosthesis Designs for the Edentulous Mandible.

OBJECTIVE This study aimed to evaluate the longitudinal clinical outcomes and biomechanical characteristics of various mandibular fixed implant-supported prostheses, focusing on cantilever presence, implant quantity, bone density, and framework materials. METHODS A retrospective clinical analysis and finite element a...

Si-Yi Chen, Yu-Qing Wang, Wen-Hao Zhao et al. · 0 citations
Oct 2026

Comparative Evaluation of Maxillary Full-Mouth Implant Prosthesis Designs: Symmetrical Segmental Splints vs. Complete Splints in Two Occlusal Schemes

In full-mouth implant prostheses of the maxilla, prosthetic framework design and occlusal pattern critically affect stress distribution and implant stability. Improper design may lead to localized stress accumulation, mechanical failure, or peri-implant bone resorption. This study aimed to compare the biom...

A. Fathi, Hossein Honarasa, Sepideh Salehi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.