Skip to content
Open access

Effect of the Mitral Valve on the Intra Ventricular Hemodynamics

Oct 2026 · International Journal for Numerical Methods in Biomedical Engineering · Vol 42 · 0 citations · 85 references
Medicine

TL;DR

The simulations indicate that the influence of MV on blood flow pattern and vortices is significant, and dissipation and TKE in the left ventricle have a strong dependence on the MV model.

Abstract

ABSTRACT To evaluate the impact of intracardiac flow features on the efficiency of the transfer of the myocardium's contractile mechanical power into blood flow hydraulic power. A time evolving 3D mesh corresponding to a patient‐specific left heart was generated from medical images to obtain the intracardiac hemodynamics via computational fluid dynamics. A parametric model of the mitral valve is used to investigate the influence of its opening area and orientation on the hemodynamics. The complete ventricular kinetic energy balance equation is established, and its terms are quantified to characterize the fraction of contractile power transferred to the blood flow. The simulations indicate that the influence of MV on blood flow pattern and vortices is significant. Dissipation and TKE in the left ventricle have a strong dependence on the MV model. Their values are higher when mimicking pathologies such as calcification of the MV (resulting in a smaller opening area), and reduced when the opening area is larger. While the orientation of the MV opening exerts a considerable impact on flow patterns, its effect on dissipation and TKE is less pronounced. For all the cases considered, the amount of energy dissipated over one cardiac cycle is a small fraction (1%–2%) of the energy at play to pump blood towards the aorta. In absence of valve leakage, the energy dissipated by viscous effect is marginal in all the healthy and pathological cases considered.

Read PDF

Similar papers

Open access Jan 2026

Influence of hematocrit-dependent blood viscosity on hemodynamics of mitral paravalvular leak

Abstract Purpose Paravalvular leak (PVL) is a pathological condition that may arise following prosthetic mitral valve implantation and is characterized by regurgitant blood flow through a gap between the prosthetic valve ring and the native cardiac tissue. High-velocity flow jets generated within the leak region may pr...

Igor Szumny, M. Kopernik · 0 citations
Open access Oct 2026

Hemodynamic evaluation for mitral valve replacement

Mitral valve replacement (MVR) alters left ventricular hemodynamics, potentially leading to thrombosis, hemolysis, and ventricular remodeling. While prior studies have assessed prosthetic valve flows, a direct in vitro comparison of vortex evolution and blood transport efficiency among native, bioprosthetic, and...

X. He, S. Feng, H. Wang et al. · 0 citations
Open access Oct 2026

Patient-Specific Analysis of Ventricular Vortex Formation and Flow Energetics in Rheumatic and Calcific Mitral Stenosis.

PURPOSE Mitral stenosis (MS) accounts for 12% of cardiac patients with single valve disease. There are two main causes: rheumatic disease of the mitral valve (MV) and mitral annular calcification (MAC). While both result in increased transmitral pressure gradients, each has unique effects on valve morphology and pathop...

Marshall Davey, Mohammad S. Hashemi, Gregg S. Pressman et al. · 0 citations
Open access Oct 2026

Effect of heart rate on hemodynamics in patient-specific intracranial aneurysms: An in vitro study

The rupture of an intracranial aneurysm (IA) has been linked to local hemodynamic environments, but it remains unclear how transient physiological states such as elevated heart rate modulate those environments, and whether different aneurysm geometries respond similarly. Here, we used volumetric particle tracking veloc...

Baha Al-Deen T. El-Khader, Nikhil Shirdade, Jana Korte et al. · 0 citations
Sep 2026

Evaluating the hemodynamic impact of different aortic valve treatments via two-way FSI

Three-dimensional two-way fluid-structure interaction simulations are used to compare the differences in hemodynamics and valvular stress distribution between native aortic valves, Ozaki leaflets, Ross leaflets, and bioprosthetic heart valve.

Zhao-Miao Liu, Xin-Yi Zhou, Yi Shi et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.