Skip to content
Open access

3-UPU-1-S Parallel Mechanism for Biomechanical Emulation of Human Ankle Motion in a Transtibial Prosthesis: Mechanical Design, Kinematic Evaluation, and Control Implementation

Sep 2026 · Machines · Vol 14, pp. 1065 · 0 citations · 29 references

TL;DR

The proposed 3-UPU-1-S mechanism was manufactured and integrated into a functional laboratory prototype with distributed ESP32-S3-based electronics, position sensing, inertial measurement, and closed-loop actuation, demonstrating the feasibility of the proposed transtibial prosthesis as an integrated laboratory platform for multiplanar transtibial-prosthesis research.

Abstract

The human ankle exhibits complex multiplanar behavior involving plantarflexion, dorsiflexion, inversion, eversion, and coupled orientation changes that are essential for balance and terrain adaptation. This work presents the design, kinematic evaluation, mechanical implementation, and control validation of a transtibial prosthesis based on a parallel robotic mechanism. Three candidate architectures, 3-SPS-1-S, 3-UPU-1-S, and 3-UCU-1-S, were compared through inverse and forward kinematics, orientational workspace, Jacobian conditioning, constructability, and mechatronic-integration criteria. The corresponding workspace coverages were 74.1%, 75.7%, and 72.2%, respectively. The 3-UPU-1-S architecture exhibited a median Jacobian condition number of 12.63, a 95th-percentile value of 20.56, no numerically singular configurations within the evaluated feasible workspace, and the highest VDI-2225 technical score (0.913), supporting its final selection. The selected mechanism was manufactured and integrated into a functional laboratory prototype with distributed ESP32-S3-based electronics, position sensing, inertial measurement, and closed-loop actuation. Experimental periodic tests showed that the decentralized PID controller achieved dominant-axis RMSE values of 3.53° in pitch during dorsiflexion–plantarflexion and 4.61° in roll during inversion–eversion. A revised formal LQRI controller was evaluated separately using the identified actuator-space model. Its nominal closed-loop system was asymptotically stable, with maxRe(λ)=−1.6896, and robustness simulations showed mean-RMSE reductions of approximately 9.4–16.6% relative to PID across the evaluated perturbation scenarios. These results demonstrate the feasibility of the proposed 3-UPU-1-S mechanism as an integrated laboratory platform for multiplanar transtibial-prosthesis research while identifying the need for future dynamic load-bearing and user-centered validation.

Read PDF

Similar papers

Open access Oct 2026

Design and Performance Analysis of 3RSS/S Ankle Rehabilitation Robot

Background/Objectives: Ankle rehabilitation robotics has garnered a lot of interest because of its ability to improve therapeutic outcomes and enable quantitative patient monitoring. The ankle has a complex biomechanical system, so the design needs to have accurate kinematics, structural stiffness, and biomechanical co...

Ahlem Hamel, Ridha Kelaiaia, Allaoua Brahmia et al. · 0 citations
Open access Sep 2026

Design and Development of 3D-Printed Models for Limb Joint Motion Simulation

This paper details the design, fabrication, and evaluation of three innovative mechatronic systems for simulating lower limb joint motion, with a focus on the hip, knee, and ankle, using 3D printing and advanced control techniques. Fabricated using CATIA V5 designs and Fused Deposition Modelling (FDM) technology, the m...

D. Prisecaru, D. Besnea, Florin Istudor et al. · 0 citations
Sep 2026

Modeling and analysis of a 5-degrees of freedom spatial parallel mechanism-based shoulder exoskeleton

This work presented a biomechanically informed model and analysis of a 5-degree-of-freedom shoulder exoskeleton, constructed on a spatial parallel mechanism with a universal-prismatic-spherical joint configuration. The primary aim of the shoulder exoskeleton mechanism was to ensure the human shoulder’s natural moveme...

A. Rout, Ekta Singla · 0 citations
Conference Oct 2026

Design and analysis of a two-DOF serial ankle rehabilitation robot

To address the problems of limited rehabilitation resources, difficulty in ensuring sufficient training intensity, and insufficient individualized training schemes for stroke patients with ankle dysfunction, this paper proposes a two-degree-of- freedom independently driven serial ankle rehabilitation robot based on the...

Yao Dai, Qing Tao, Chen-Yao Liu et al. · 0 citations
Open access Sep 2026

A Novel Parallel Exoskeleton for Wrist Rehabilitation: Conceptual Design, Kinematics, and Singularity Analysis

The design and kinematic validation of a novel 3-DOF spherical parallel exoskeleton featuring base-fixed actuators featuring base-fixed actuators featuring exponential rotational matrices is presented, providing systematic derivations of equations in compact form.

Samet Yavuz, S. Himmetoglu · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.