Within the limitations of this study and under the simulated immediate postoperative loading condition, shorter implants, particularly 5 mm implants, showed a favorable biomechanical response.
Abstract
Dental rehabilitation of fibula free flap mandibular reconstructions can be limited by the reduced vertical bone height available for implant placement. This study evaluated the biomechanical influence of ultra-short, extra-short, and conventional implants in a reconstructed fibula. Methods: A patient-specific finite element model of a fibula-reconstructed mandible was developed. Three splinted implants with a diameter of 4 mm and lengths of 3, 5, or 12 mm were compared under postoperative unilateral molar loading. Von Mises stresses were evaluated in the implants, fibula, residual mandible, and fixation plates, while equivalent elastic strain was assessed in peri-implant bone. Results: Implant length had minimal influence on implant stress (36.8–37.1 MPa) and fibular cortical bone stress (52.5–53.1 MPa). The 5 mm implants produced the lowest peri-implant strains and the lowest posterior reconstruction-plate stress (71.3 MPa), compared with 75.4 MPa for 3 mm and 107.8 MPa for 12 mm implants. The 12 mm implants generated greater apical strain concentrations, exceeding the adopted mechanobiological threshold around the central and mesial implants. Conclusions: Within the limitations of this study and under the simulated immediate postoperative loading condition, shorter implants, particularly 5 mm implants, showed a favorable biomechanical response.
This study aimed to evaluate the biomechanical effects of different posterior support strategies in borderline atrophic mandibular full-arch implant rehabilitation, where treatment decision-making remains challenging, using three-dimensional finite element analysis (FEA). A totally edentulous mandibular model was gener...
M. Toprak, Ahmet Talha Osmanoğlu, Orhan Kazan et al.· Journal of Applied Biomateri...· 0 citations
Rehabilitation of the atrophic edentulous maxilla remains biomechanically challenging, particularly regarding optimal posterior implant configuration. Therefore, it is of interest to compare the two All-on-six configurations using 2D and 3D models reconstructed from CBCT data: tilted posterior implants with distal cant...
In full-mouth implant prostheses of the maxilla, prosthetic framework design and occlusal pattern critically affect stress distribution and implant stability. Improper design may lead to localized stress accumulation, mechanical failure, or peri-implant bone resorption.
This study aimed to compare the biom...
A. Fathi, Hossein Honarasa, Sepideh Salehi et al.· Journal of Oral Implantology· 0 citations
Objective. To evaluate the stress-strain state of bone tissue supported by six dental implants under various types of occlusal loading by finite element analysis.
Materials and methods. A three-dimensional finite element model of the mandibular segment with six implants and a fixed bridge prosthesis was developed. The...
S. Serebryanyy, A. Muraev, K. Salekh et al.· Perm Medical Journal· 0 citations
The use of dental implant therapy has now become part and parcel of modern prosthodontic rehabilitation with predictable results in replacement of missing teeth. Traditionally, the longer implants are desirable as they are likely to have more bone-to-implant contact and be biomechanically superior. Anatomical limitatio...
Poonam Rai, Shrushti Sukalkar, S. Dharmadhikari et al.· International Journal of Dru...· 0 citations
PURPOSE
The aim of this study was to evaluate the influence of anterior cantilever length on stress distribution in subperiosteal implants (SI) fabricated from titanium and 60% carbon fiber-reinforced polyetheretherketone (PEEK) with one-piece and two-piece configurations using finite element analysis.
MATERIALS AND...
Bersu Bedirhandede, B. Güney, D. Doğan et al.· Journal of Prosthodontics· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.