Skip to content
Review Open access

A device profile on the MAGiC ablation catheter for treatment of cardiac arrhythmia.

Sep 2026 · Expert Review of Medical Devices · pp. 1-8 · 0 citations · 12 references
Medicine

Abstract

INTRODUCTION Catheter ablation is standard of care for cardiac arrhythmias, but conventional catheters are still limited by single-plane steering, variable tissue contact, and high irrigation demands, particularly in complex anatomy. Robotic magnetic navigation (RMN) addresses several of these constraints, but it has long depended on a first-generation radiofrequency catheter. AREAS COVERED This device profile reviews the design, mechanism of action, available clinical evidence, regulatory status and future development of the MAGiC magnetic ablation catheter, the first purpose-built catheter for the Stereotaxis RMN platform. The catheter is used across the full arrhythmia spectrum, including supraventricular tachycardias, atrial fibrillation, and ventricular arrhythmias, with complex and congenital anatomy among its most demanding applications. The evidence is drawn from its first-in-human study, supporting bench and platform data, and a structured search of the peer-reviewed literature. EXPERT OPINION Early experience points to improved catheter stability, stable tip temperatures, and reduced irrigation relative to the predecessor RMN catheter. The evidence base remains small, single-arm and partly manufacturer-sponsored, however, and comparative and long-term data are not yet available.

Read PDF

Similar papers

Open access Oct 2026

One thousand cases of Pulsed-Field Ablation: Real-World insights

Pulmonary vein isolation (PVI) is the standard catheter-based treatment for atrial fibrillation (AF). Due to its safety profile and efficacy, pulsed field ablation (PFA), a non-thermal energy, has been increasingly adopted as the default strategy across many centers. We aimed to analyse the real-world efficacy an...

S. Azevedo, R. Carvalho, J. Pereira et al. · 0 citations
Review Open access Oct 2026

The future of PFA in cardiac ablation procedures

Abstract Pulsed field ablation (PFA) has rapidly emerged as a major development in catheter ablation, with increasing clinical adoption driven by procedural efficiency and a favorable safety profile compared with thermal energies. This article summarizes the future directions of PFA in electrophysiology, focusing on te...

J. Andrade, S. Asirvatham, M. Hocini et al. · 0 citations
Nov 2026

Abstract 13377: A Detailed Electro-Anatomical Assessment of Patient Undergoing Repeat Catheter Ablation After Initial Pulsed-Field Ablation for Atrial Fibrillation

Introduction/Background: Pulmonary vein isolation (PVI) serves as the cornerstone of catheter ablation for rhythm control of atrial fibrillation (AF). Posterior wall isolation (PWI) has long been used in select patients as an adjunctive therapy, particularly in patients with persistent atrial fibrillation. Using tra...

Kavin Sundaram, Perla Canales, Cassidy Salow et al. · 0 citations
Review Open access Oct 2026

Controlling pulsed field ablation efficacy during ablation procedures

Abstract Pulsed field ablation (PFA) has rapidly emerged as a promising ablation modality for the treatment of cardiac arrhythmias because of its myocardial tissue preferential ablation and favourable safety profile. However, procedural control of lesion formation and reliable assessment of lesion durability remain imp...

M. Cespón-Fernández, R. Davalos, T. Kueffer et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.