Skip to content
Conference

Research on Thermal Power-Flywheel Energy Storage Cooperative Variable Load Control Strategy Based on Closed-Loop Constraints

Aug 2026 · 2026 6th Power System and Green Energy Conference (PSGEC) · pp. 832-837 · 0 citations · 6 references

Abstract

The grid integration of high-proportion new energy leads to frequent fluctuations in grid power and frequency, which raises higher requirements for the AGC variable load regulation performance of thermal power units. Restricted by inherent equipment characteristics, conventional thermal power units fail to meet the demands of high-frequency and fast regulation. Taking a 350 MW thermal power unit as the research object, this paper establishes the mechanism models of the unit and flywheel energy storage system, and analyzes their regulation characteristics and complementary advantages. An adaptive rate limiting control scheme is designed to conduct frequency division processing on AGC commands. The flywheel energy storage is adopted to suppress high-frequency and short-term power fluctuations, while the thermal power unit undertakes low-frequency and continuous load changes. Meanwhile, closed-loop constraints are constructed combined with the deviation of unit main steam pressure and the state of charge (SOC) of flywheel energy storage to ensure stable operation of the unit and prevent overcharge and overdischarge of the energy storage. Verified by variable load simulations under multiple operating conditions, the results show that the proposed cooperative control strategy for thermal power and energy storage can effectively optimize the unit operating state, greatly improve the AGC command tracking accuracy and dynamic response speed of thermal power units, and possess practical engineering application value.

View source

Similar papers

Open access 2026

Primary Frequency Regulation Strategy for Thermal Power Units Assisted by Flywheel Energy Storage Based on Fuzzy Adaptive Control

: In response to the inadequacies in State of Charge (SOC) management, limited dynamic adaptability, and the potential for frequency deviations caused by SOC self-recovery following primary frequency regulation in existing flywheel energy storage-assisted thermal power generation units, this study proposes a fuzzy adap...

Qu-Yan Zhou, Hong-Ming Hu, Hong-Sheng Wu et al. · 0 citations
Open access Aug 2026

An Improved Droop Control Strategy for Primary Frequency Regulation in Islanded Microgrids Using Distributed Energy Storage

The large-scale integration of renewable energy generation into the grid has led to increased frequency fluctuations in the power grid. Distributed energy storage systems, with their rapid response times, serve as a critical resource for primary frequency regulation. Traditional constant-droop control cannot adjust the...

Hao He, Chunjiang Zhang, Feng Gao et al. · 0 citations
Open access Oct 2026

Optimal Configuration and Operation of Grid-Forming Electro-Hydrogen Energy Storage in New Power System Considering Power and Energy Balance

Aiming to address the problem of power and energy imbalance caused by a high proportion of new energy grid connections, the influence of fluctuation characteristics of both sides of the load on power and energy balance of new power systems is analyzed, and an evaluation system including core indicators such as power ba...

Yi Chai, Yun-Fei Tian, Qing-Hai Hao et al. · 0 citations
Open access Aug 2026

SOC- and RoCoF-Aware Bounded Adaptive Droop Control of Battery Energy Storage for Fast Frequency Response in Islanded Renewable Energy Systems

High penetration of converter-interfaced photovoltaic and wind generation reduces the effective inertia of islanded renewable energy systems and makes frequency stability more sensitive to load and renewable-power disturbances. This paper proposes a bounded adaptive droop framework for battery energy storage system (BE...

Jia-Cheng Li, Meng-Han Xiao, Qi-Xiang Huang et al. · 0 citations
Sep 2026

Frequency regulation strategy for wind-storage systems based on improved torque limit control

With a high proportion of wind power connected to the power grid, the decline of system inertia leads to the increasingly prominent problem of frequency stability. Because of the limited kinetic energy of the rotor, wind turbines (WTs) are prone to causing secondary frequency drop (SFD) when participating in frequency...

Jin Ren, Dan-Yi Su, Bo Wei · 0 citations
Open access 2026

Capacity configuration of energy storage for wind farm primary frequency regulation support

With the increasing penetration of wind power in modern power systems, primary frequency regulation (PFR) capability has become a mandatory requirement for grid integration. Drawing on the PFR mechanisms of conventional thermal power plants, this paper proposes control strategies for wind farms, specifically including...

Ling Liu · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.