Skip to content

Is technical difficulty associated with the accuracy of patient-specific implants for maxillary repositioning in minimally invasive orthognathic surgery?

Oct 2026 · International Journal of Oral & Maxillofacial Surgery · 0 citations · 25 references
Medicine

TL;DR

It is demonstrated that PSI-assisted minimally invasive orthognathic surgery achieves clinically acceptable accuracy across varying levels of technical difficulty, supporting its reliable use even in technically demanding cases.

Abstract

The use of patient-specific implants (PSIs) in minimally invasive orthognathic surgery remains limited due to concerns about technical difficulty and restricted intraoperative exposure. Whether increasing maxillary movement technical difficulty compromises the accuracy of PSI-assisted minimally invasive surgery remains unclear. This retrospective cohort study evaluated the accuracy of maxillary repositioning using PSIs in minimally invasive bimaxillary orthognathic surgery and its relationship to technical difficulty. Consecutive patients treated at the University of Texas Health San Antonio between June 2023 and September 2025 were included if they underwent bimaxillary minimally invasive orthognathic surgery with complete preoperative and postoperative cone-beam computed tomography records. Patients with craniofacial syndromes, comorbidities affecting postsurgical healing, or those undergoing single-jaw surgery were excluded. Technical difficulty was defined by the presence of maxillary advancement >7 mm, maxillary segmentation, or posterior maxillary impaction >1.5 mm. Accuracy was measured as the root mean square linear discrepancy between planned and postoperative maxillary positions. Demographic characteristics and malocclusion type were recorded as covariates. Thirty-six patients were included, with a mean age of 27 years. Comparisons were made across advancement magnitude, segmentation status, and posterior impaction. No statistically significant differences in root mean square discrepancies were observed across landmarks or axes after correction for multiple comparisons, with the lowest observed probability value being 0.02. These findings demonstrate that PSI-assisted minimally invasive orthognathic surgery achieves clinically acceptable accuracy across varying levels of technical difficulty, supporting its reliable use even in technically demanding cases.

View source

Similar papers

Oct 2026

The use of patient-specific implants: a promising strategy to reduce rigid external distractor-associated complications in syndromic craniosynostosis.

BACKGROUND Midface distraction osteogenesis (DO) with rigid external distraction (RED) is an established technique for treating severe midfacial hypoplasia in patients with syndromic craniosynostosis. However, halo-type distractors are associated with substantial device-related complications, particularly at the crania...

Jennifer Fuchs, M. Appel, S. Zittel et al. · 0 citations
Open access Oct 2026

Comparison of Connected Mini-Implants and Surgical Mini-Plates for Skeletal Anchorage During Maxillary En-Masse Retraction: A Prospective Clinical Study

Objective: To compare the clinical performance and skeletal stability of connected mini-implants and surgically placed mini-plates as skeletal anchorage systems during maxillary anterior en-masse retraction. Materials and Methods: A prospective split-mouth clinical study was conducted on 10 patients requiring maximum...

S. Saravanan, K. S · 0 citations
Open access Oct 2026

Accuracy of maxillary positioning in semi-guided orthognathic surgery using 3D-printed cutting guides and bending plates: A retrospective study.

Preliminary findings suggest that semi-guided orthognathic surgery can transfer the VSP with deviations within the range observed for the conventional splint-based workflow, and may represent a clinically promising alternative to conventional splint-based workflows and fully patient-specific implant-based approaches in...

M. Beyer, Oliver V. Waldvogel, Lea Alig et al. · 0 citations
Open access Sep 2026

Novel Reverse Zygomatic Implant Approach: Expanded Cadaveric Validation, Surgical Accuracy, and Comparison of Orbital Access Routes—Part 2

Guided reverse zygomatic implant placement was technically feasible and reproducible regarding implant stability in this cadaveric model, however, cortical fracture risk and incomplete prosthetic correspondence indicate that further optimization and prospective clinical validation are required before routine clinical a...

A. Ferrer-Fuertes, F. Cuesta-González, R. Sieira-Gil et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.