Skip to content
Open access

Beat-to-Beat Action Potential Duration Variability, Not Duration, Reflects β-Adrenergic Stimulation-Induced Repolarization Instability

Oct 2026 · medRxiv · 0 citations · 30 references
Medicine

TL;DR

It is demonstrated that beat-to-beat variability in action potential duration (APD), a cellular surrogate of the QT interval, better stratifies proarrhythmic risk than mean APD prolongation alone and suggests that QT interval variability may improve risk stratification and provide a more robust mechanistic foundation for drug safety evaluation.

Abstract

Instability of the cardiac electrical system is a major cause of life-threatening arrhythmias. Current safety guidelines have traditionally emphasized QT interval prolongation on the electrocardiogram (ECG) as a primary biomarker of proarrhythmic risk. However, this approach does not capture all forms of electrical instability. In this study, we demonstrate that beat-to-beat variability in action potential duration (APD), a cellular surrogate of the QT interval, better stratifies proarrhythmic risk than mean APD prolongation alone. Using a validated computational model of a human ventricular myocyte, we simulated the effects of the {beta}-adrenergic agonist isoproterenol (ISO). Increasing the ISO concentration shortened mean APD but paradoxically increased beat-to-beat APD variability, measured as the standard deviation of APDs. In our simulations, the emergence of early afterdepolarizations (EADs), abnormal oscillations of the membrane potential during the plateau phase of the action potential, at higher ISO concentrations was consistently preceded by a marked rise in APD variability, even while mean APD was reduced. Mechanistic analysis revealed that ISO-induced enhancement of L-type Ca2+ current (ICaL) and slow delayed rectifier K+ current (IKs) steepens the APD restitution slope, which reflects action potential instability, even when the net effect is a reduction in APD. These results support APD variability as a more sensitive and mechanistically plausible marker of proarrhythmic risk than APD prolongation alone. Our findings suggest that QT interval variability may improve risk stratification and provide a more robust mechanistic foundation for drug safety evaluation.

Read PDF

Similar papers

Open access Oct 2026

Dynamics of P wave Morphological Variability Preceding the Onset of Atrial Fibrillation.

Although the problem of predicting atrial fibrillation (AF) has been extensively studied, the electrophysiological changes that precede AF onset remain insufficiently understood. From a clinical perspective, better understanding of such changes should facilitate future monitoring, prediction strategies, and therapeutic...

M. Noriega, A. Martín-Yebra, M. Stridh et al. · 0 citations
Open access Oct 2026

Non-invasive electrocardiographic imaging of torsades de pointes in an ovine model of drug-induced QT prolongation: recovery dispersion sets the stage, and abnormal impulse formation pulls the trigger

Torsades de pointes (TdP) arise from a dynamic spatiotemporal interplay between arrhythmogenic substrate and triggering events. Most existing in-vivo models investigating TdP rely on invasive surgical cardiac access, which alters electromechanical function of the heart and autonomic influences, thus limiting thei...

P. Deissler, M. Obeidat, J. Stoks et al. · 0 citations
Open access Oct 2026

The autonomic-ventricular coherence index: a novel single-lead ECG method with acquisition-dependent discrimination

Background Autonomic regulation and the heart's electrical activity are both central to normal cardiac function, yet there is currently no direct way to capture the interaction between them from a standard ECG. This paper introduces the Autonomic–Ventricular Coherence Index (AVCI), a single-lead ECG method that measure...

Jayasree R, C. G · 0 citations
Open access Sep 2026

Electrophysiological dependent antiarrhythmic drug response in population-based models of paroxysmal atrial fibrillation

Response to antiarrhythmic drugs varies markedly across patients with atrial fibrillation (AF), suggesting that treatment efficacy depends on the interaction between drug-specific mechanisms and patient-specific electrophysiological substrate. Here, we used population-based computational models to investigate how elect...

Violeta Puche-García, Laura Martinez-Mateu, David Filgueiras-Rama et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.