Efficacy and Safety Analysis of Single-Port Robotic Assisted Cholecystectomy Using a Novel Surgical Platform: A Bicentre, Single-Arm, Prospective Phase II Clinical Study.
Aug 2026· The international journal of medical robotics + computer assisted surgery : MRCAS· Vol 22 5, pp.
e70221
· 0 citations· 16 references
Medicine
TL;DR
The novel single-port robot demonstrated feasibility and safety in cholecystectomy with effective triangulation, controlled operative time and reduced trauma.
Abstract
Background
Single-port robotic cholecystectomy offers minimally invasive benefits. This trial evaluated the feasibility and safety of a novel system, MicroPort SA-1000.
Methods
In this dual centre, single-arm, prospective study, eligible patients underwent single-port robot-assisted cholecystectomy with MicroPort SA-1000. The primary endpoint was the completion rate, while secondary endpoints included estimated blood loss, operating time, hospital length of stay and complications.
Results
From June 2023 to December 2023, a total of 44 patients from two centres were enrolled, and all patients underwent single-port robot-assisted cholecystectomy without conversion. The median EBL was 10 mL (range 5-200 mL). The total operative time was 88.43 ± 25.87 minutes. The median LOS was 2.5 days (range 1-7 days). No serious surgery-related adverse events were observed.
Conclusions
The novel single-port robot demonstrated feasibility and safety in cholecystectomy with effective triangulation, controlled operative time and reduced trauma. Larger studies are needed to validate its performance across different surgical fields.
TRIAL REGISTRATION
This study was registered at https://www.chictr.org.cn/showproj.html?proj=258677 (ChiCTR2500107401).
Objective: This study aimed to evaluate the safety and feasibility of robotic-assisted cholecystectomy using the CMR
Versius system and to characterize operative performance during the initial institutional experience.
Study design and setting: This retrospective cohort study took place at Surgical Unit 4, Ward 21, Jin...
Mansab Ali, Hamra Afridi, S. Dawani et al.· Journal of Bahria University...· 0 citations
In this early multicenter experience, SSRDP using the da Vinci SP platform was feasible and achieved acceptable perioperative outcomes comparable to those of Xi-SSRDP.
Y. Choi, Sung Hyun Kim, Young-Dong Yu et al.· The international journal of...· 0 citations
Objective
This study was conducted to investigate the safety and feasibility of a newly designed single-port trocar that allows peritoneal catheter placement without the need for additional abdominal puncture during laparoscopy-assisted ventriculoperitoneal shunt surgery.
Methods
This prospective, single-arm pilot st...
Jong-Min Lee, M. Kim, In Kyu Park et al.· Journal of Korean Neurosurgi...· 0 citations
The findings of this single-arm meta-analysis indicate that Senhance-assisted robotic cholecystectomy is both safe and feasible, demonstrating a high surgical success rate, acceptable operative times, and a short postoperative hospital stay.
Ye Tao, Wen-Tao Lei, Xin-Min Niu et al.· Journal of Robotic Surgery· 0 citations