Aug 2026· 2026 4th International Conference on Power, Grid and Energy Storage (PGES)· pp. 637-642· 0 citations· 11 references
Abstract
In this paper, the pulse train (PT) control scheme is employed for unbalanced current mitigation in three-phase PWM rectifiers under unbalanced three-phase input voltage conditions. In the outer voltage loop, to prevent the impact of the output voltage double-frequency ripple on the current inner loop, the moving average filter (MAF) is employed. Meanwhile, all-pass filter (APF)-based orthogonal signal generator (OSG) and inverse Clark transformation are employed to construct balanced three-phase current references. In the inner current loop, the PT control scheme is employed to force the three-phase currents to track the balanced references. The proposed control scheme is implemented in the stationary reference frame without rotational coordinate transformation, which simplifies the implementation. Simulation results demonstrate that the proposed control scheme for three-phase PWM rectifiers can effectively mitigate the unbalanced degree and the harmonic distortion of the three-phase currents.
In high-speed railway traction drive systems, the deployment of Pulse Width Modulation (PWM) rectifiers represents an effective solution for mitigating harmonic pollution on the AC supply network, enhancing the power factor, and achieving energy efficiency due to the capability for seamless energy conversion between tr...
T. Pham Van, Thắm Mai Văn· The Transport and Communicat...· 0 citations
This article proposes a robust control strategy to minimize grid current harmonics in three-phase diode rectifier-fed permanent magnet synchronous motor (PMSM) drives featuring a small DC-link capacitance. First, a virtual impedance-based active damping scheme is introduced to emulate a series R-C damper. This suppress...
This paper proposes a robust sliding-mode control (SMC) strategy for a single-phase PWM AC–DC boost rectifier intended for wireless electric vehicle charging systems. The controller is designed to achieve two main objectives: accurate synchronization of the input current with the grid voltage for power-factor correctio...
Fatima Mesbah, Youssef El-Kazini, Nasreddine Haqiq et al.· Engineering Research Express· 0 citations
This paper deals with an active front-end converter (AFEC) for a 5-ϕ inverter-fed induction motor (IM) drive. Multi-phase IM drive stands as an evolving domain of electrical drive usages. Supply from the grid is prone to be unbalanced and affects the input power quality of adjustable multi-phase IM drives. This work pr...
C. Kalaivani, D. Raja, S. Sivasakthi et al.· International Journal of App...· 0 citations
This paper proposes an active power decoupling (APD) control method based on modulated model predictive control (MMPC) with two state variables to reduce dc-link voltage ripple under unbalanced and distorted three-phase grid conditions. The dc-link power ripple is analyzed by considering harmonic components of the grid...
Minji Kim, Yu-Jin Shin, Do-Hoon Lee et al.· IEEE Access· 0 citations
This paper presents a vector-control-based strategy to regulate the current in a dual three-phase voltage-source inverter (VSI)-fed Six-terminal nine-phase (6T9P) induction motor. The 6T9P winding layout offers the benefits of a lower inverter leg count than the conventional nine-phase topology, thereby reducing contro...
Kayembe Ben Malaba, M. Muteba, Gulshan Sharma· Machines· 0 citations