Sep 2026· Journal of Physics, Conference Series· Vol 3328, pp. 012033· 0 citations· 9 references
Physics
TL;DR
Results confirm that conflict-aware fusion and topology-based localization substantially improve diagnostic reliability over existing methods.
Abstract
This paper presents a multi-source data-fusion framework for fault diagnosis and early warning of relay protection secondary circuits in smart substations. The proposed method integrates seven data sources—SV statistics, GOOSE statistics, IED self-check records, MMS alarms, physical-link measurements, time-synchronization data, and SCD configuration records—through credibility-weighted Dempster–Shafer evidence fusion to manage uncertain and conflicting information. A graph-based topology model localizes faulty elements via suspicion propagation, while an adaptive health index tracks degradation trends for graded early warning. Experimental validation on a 110 kV IEC 61850 hardware-in-the-loop platform demonstrated 97.1% diagnostic accuracy, 1.8% false-alarm rate, and 95.6% localization accuracy, outperforming single-source analysis by 25.3 percentage points. The framework provided attention-level warnings 53.1 hours before functional failure, enabling preventive maintenance. Results confirm that conflict-aware fusion and topology-based localization substantially improve diagnostic reliability over existing methods.
Gas - insulated switchgear (GIS) occupies a strategically important position in compact, high-voltage substations, yet concealed insulation defects can develop before conventional protection operates. Partial discharge (PD) monitoring offers a means of recognising such deterioration during service, although detection a...
Faisal Aleem· International Journal of Adv...· 0 citations
- High-voltage gas-insulated switchgear (GIS) is central to compact, reliable transmission substations, yet its apparent reliability can conceal insulation defects, mechanical degradation, gas-system anomalies, thermal problems, and ageing mechanisms that become costly when detected only after failure. This review deve...
Faisal Aleem· Iconic research and engineer...· 0 citations
Smart electrical distribution networks contain distributed energy resources, power-electronic interfaces, smart meters, phasor measurement units, intelligent electronic devices, and communication links that generate large volumes of operating data. These data enable a shift from conventional threshold-based protection...
Gyeong Trivedi-Rao· International Journal of Adv...· 0 citations
Smart oilfields increasingly depend on an integrated electrical distribution system, instrument loops, control networks, and data infrastructure. Degradation of this often-invisible infrastructure can significantly affect production and process safety. This paper describes a risk-based quality assurance framework which...
Azhar Yousuf· Iconic research and engineer...· 0 citations
To tackle the drawbacks of traditional manual periodic inspection for converter-station equipment, such as delayed data acquisition, insufficient monitoring precision, and poor early warning capacity for latent defects, this paper develops a full-station defect-free intelligent management and control system. Integratin...
Dan-Hui Hu, Ze-Qi Huang, Hai-Ming Liu et al.· AIP Advances· 0 citations
This study addresses the persistent challenge of coordinate drift in substation monitoring systems, where prolonged operation leads to progressive deviations from preset configurations. An optimized BN-FTA framework that integrates Bayesian Networks (BNs) with Fault Tree Analysis (FTA) is proposed to improve anomaly de...