Skip to content
Open access

Hemibrain growth as a biomarker for whole-brain growth.

Sep 2026 · Journal of Neurosurgery: Pediatrics · pp. 1-11 · 0 citations · 42 references
Medicine

TL;DR

Hemibrain volume estimation of the unaffected hemisphere offers a feasible method for assessing brain growth over time and can be automated using a highly accurate AI pipeline, providing a valuable tool for monitoring brain growth in pediatric hydrocephalus patients with shunts.

Abstract

Objective

Accurate estimation of CSF and brain volume is an important component in evaluating hydrocephalus treatments, including shunt and endoscopic third ventriculostomy procedures. While MRI-based segmentation typically provides precise measurements, metallic artifacts from implanted shunts in patients with hydrocephalus can impede accurate volume determination. This study introduces a method for assessing brain growth in hydrocephalus patients using artifact-affected MR images and presents an efficient, automated AI-based pipeline for hemibrain segmentation and subsequent volume assessment.

Methods

This study utilizes imaging data from the Endoscopic versus Shunt Treatment of Hydrocephalus in Infants trial. Pre- and postoperative T2-weighted MR images were obtained in 75 patients. Hemibrain growth curves for the artifact-free hemisphere are proposed to assess postoperative brain growth in MR images with metallic shunt artifacts. An AI-based hemibrain volume estimation pipeline was developed, consisting of a brain/CSF segmentation model and a hemibrain mask generator. Segmentation labels, including left/right hemibrain masks and brain/CSF segmentation maps, were created. The AI pipeline was trained and validated using a manually segmented data subset. The volumes of left and right brain hemispheres after surgery were calculated and analyzed.

Results

Postoperative hemisphere volume ratios approached the normal ratio and remained constant over time, confirming the feasibility of using hemibrain measurements as proxies for whole-brain volume assessment in the presence of metallic artifacts. Additionally, the AI-based pipeline demonstrated high accuracy in generating hemibrain masks and segmenting brain/CSF, effectively automating the process of hemibrain volume estimation.

Conclusions

Hemibrain volume estimation of the unaffected hemisphere offers a feasible method for assessing brain growth over time. This process can be automated using a highly accurate AI pipeline, providing a valuable tool for monitoring brain growth in pediatric hydrocephalus patients with shunts.

Read PDF

Similar papers

Open access Sep 2026

Quantitative MRI Volumetry as a Potential Neuroimaging Biomarker in Levetiracetam-Treated Epilepsy

Background/Objectives: Quantitative magnetic resonance imaging (MRI) volumetry may provide an objective approach for detecting subtle longitudinal structural brain changes in patients with epilepsy. This retrospective longitudinal study investigated regional and global brain volume changes observed during levetiracetam...

Sibel Çıplak, Serkan Ünlü · 0 citations
Open access Oct 2026

A large, comprehensive labeled MRI dataset of the human lateral ventricle choroid plexus

The choroid plexus (ChP) is a highly vascularized structure located in the brain ventricles that plays important roles in multiple central nervous system functions. ChP enlargement has been implicated in many neuropsychiatric conditions such as multiple sclerosis, depression, schizophrenia, and Alzheimer’s disease. How...

Ling-Yu Huang, V. Zeng, Nicolas Raymond et al. · 0 citations
Open access Oct 2026

Structural changes of the cerebral gray matter in patients with temporal lobe epilepsy

The formation of an epileptogenic network is considered to be the primary cause of resistance to surgical treatment of temporal lobe epilepsy (TLE). Modern magnetic resonance imaging (MRI) post-processing techniques enable a detailed investigation of the microstructural changes underlying this network. Objective: t...

M. Maksimova, M. Krotenkova, A. D. Shitova et al. · 0 citations
Open access Oct 2026

Automated Cerebrospinal Fluid Flow Quantification in Hydrocephalus Using Phase‐Contrast Magnetic Resonance Imaging

ABSTRACT Quantitative cerebrospinal fluid (CSF) flow analysis with phase‐contrast magnetic resonance imaging depends on segmentation and is affected by operator variability. This cohort method‐comparison study evaluated whether a flow‐aware deep learning (DL) model provides reproducible C2–C3 CSF segmentation and flow...

E. A. Rodríguez Martínez, Pan Liu, K. Owashi et al. · 0 citations
Oct 2026

Optimization of phase-contrast MRI shunt flow measurement across multiple scanners for the management of hydrocephalus.

OBJECTIVE Ventricular shunts divert CSF in patients with hydrocephalus, often providing lifesaving intervention. Untreated shunt failure can lead to increased intracranial pressure and subsequent neurological injury. Phase-contrast MRI (PC-MRI) is a noninvasive technique to assess shunt function by measuring shunt flow...

Jason M. Toliao, Matthew T. Borzage, C. González-Zacarías et al. · 0 citations
Open access Oct 2026

Non-contrast MRI reliably captures perfusion abnormalities in status epilepticus.

Non-contrast pCASL detected SE-related peri-ictal perfusion abnormalities and showed significant quantitative correspondence with DSC-derived CBF and CBV in parenchymal hyperperfusion, supporting its use as a pragmatic approach for clinically oriented evaluation.

Lukas Machegger, Pilar Bosque Varela, J. Steinbacher et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.