The findings demonstrate the potential of phasor-based FLIM as a sensitive optical imaging modality for detecting subtle microenvironmental changes in skin tissue and differentiating responses to multiple environmental stressors and highlight the broader applicability of FLIM in biomedical optics, skin research, and environmental exposure assessment.
Abstract
Skin tissue is continuously exposed to a range of environmental stressors that can induce subtle biochemical and structural changes at the microscopic level. Consequently, there is growing interest in sensitive, non-invasive optical techniques capable of detecting these alterations for biomedical research and tissue characterisation. In this study, we investigated the utility of fluorescence lifetime imaging microscopy (FLIM) combined with phasor analysis as a label-free approach for detecting and differentiating tissue responses to environmental exposures. Porcine skin samples were subjected to ultraviolet (UV) radiation, 26 GHz fifth-generation (5G) millimetre-wave (mmWave) radiation, and a combined UV+mmWave exposure protocol. Following controlled irradiation, FLIM was employed to spatially map tissue fluorescence signatures and characterise exposure-induced changes within the skin microenvironment. Phasor-based analysis enabled visualisation and quantification of complex fluorescence lifetime distributions without the need for predefined fitting models, providing enhanced sensitivity to subtle tissue alterations. Distinct fluorescence lifetime patterns were observed among the exposure groups, with quantitative analysis revealing measurable differences in lifetime heterogeneity between UV-exposed, mmWave-exposed, and combined UV+mmWave-exposed tissues. The combined exposure group exhibited the greatest deviation from baseline fluorescence lifetime characteristics, while sunscreen-treated samples showed partial preservation of native fluorescence lifetime distributions, indicating a protective effect. Collectively, these findings demonstrate the potential of phasor-based FLIM as a sensitive optical imaging modality for detecting subtle microenvironmental changes in skin tissue and differentiating responses to multiple environmental stressors. The results further support the use of fluorescence lifetime biomarkers for label-free tissue characterisation and highlight the broader applicability of FLIM in biomedical optics, skin research, and environmental exposure assessment.
Fluorescence lifetime imaging microscopy (FLIM) is an advanced microscopy technique that enables label-free, non-destructive optical metabolic imaging (OMI) of biological materials at spatiotemporal resolution. Accordingly, FLIM has emerged as a widely used platform for multi-scale characterization of the tumor mic...
Julian Najera, Hao Chen, Scott S. Howard et al.· Cellular and Molecular Bioen...· 0 citations
Microplastics (MPs), as emerging pollutants of global concern, urgently require rapid monitoring techniques for effective ecological risk management. Fluorescence microscopy is widely utilized for capturing the morphology of MPs but remains limited in polymer-type discrimination and differentiation from environmental m...
Yu-Jiao Jiang, Qian Wu, Xiao Shu et al.· Analytical Chemistry· 0 citations
In vivo fluorescence lifetime imaging (FLI) is an advanced optical imaging modality with the capability to reveal additional biological information compared to fluorescence intensity (FI) imaging. In addition to enabling tissue discrimination based on microenvironmental variations, lifetime contrast allows the differen...
Elisa Chazeau, Hassan Al Sabea, S. Janssen et al.· ACS Omega· 1 citation
It is demonstrated that in vivo fluorescence imaging is a sensitive and non-invasive tool for real-time monitoring of ROS in harvested produce and offers new perspectives for investigating oxidative stress dynamics relevant to postharvest quality management of fruits and vegetables.
Mohamed Hawali Bata Gouda, C. Cordella, A. Duarte-Sierra· Frontiers in Plant Science· 0 citations
Precise quantification of tissue oxygenation (pO
2
) is important for understanding tumor progression and evaluating metabolic therapies. However, conventional intensity-based optical oxygen sensors suffer from severe signal fluctuations for in vivo measurements due to tissue scattering and excitation conditions. H...
Zhu-Li Wu, Ming-Yue Gong, Yao Lu et al.· Journal of Innovative Optica...· 0 citations