TL;DR

Assessment of the blood contact angle of HA/PEEK surfaces before and after laser modification found reduced wettability under the laser parameters investigated, specific to the laser parameters evaluated.

Abstract

Introduction Polyetheretherketone (PEEK) is increasingly used in dental implantology because of its biomimetic properties. However, its application is limited by bio-inertness and inherent hydrophobicity, which may affect early biological interactions. PEEK surfaces are often coated with bioactive materials such as hydroxyapatite (HA), but it remains unclear how subsequent surface modification techniques such as laser treatment affect their wettability. There is still limited data on blood surface interactions in laser-treated HA/PEEK composites. This study was designed to assess and compare the blood contact angle of HA/PEEK surfaces before and after laser modification. Materials and methods Twenty-one HA-coated PEEK discs were evaluated, with each individual disc serving as the experimental unit for contact-angle assessment. Blood contact-angle measurements were obtained from each disc before laser treatment and repeated on the same disc following laser surface modification, resulting in paired observations. Hydroxyapatite (HA) nano powder was applied to the PEEK surfaces using friction stir processing (FSP). Fresh EDTA-anticoagulated whole blood obtained from a single donor was used as the test fluid. To minimize variability, blood was collected from the same donor and venipuncture site, and all measurements were performed by the same operator under standardized conditions. Following baseline contact-angle measurement, the HA/PEEK discs were treated using an Er,Cr:YSGG laser (2,790 nm, 1 W) for 4 s at a working distance of 10 mm under 5% water and 95% air spray, after which contact-angle measurements were repeated. Pre- and post-laser contact-angle measurements were compared using the Wilcoxon signed-rank test, with statistical significance set at p < 0.05. Results Pre-laser HA/PEEK surfaces exhibited lower blood contact angles than the corresponding post-laser surfaces, indicating greater wettability before laser modification. Following laser treatment, blood contact angles increased, indicating reduced wettability under the laser parameters investigated. Conclusion The observed reduction in wettability was specific to the laser parameters evaluated in this study.

Read PDF

Similar papers

Open access Oct 2026

Human Osteoblast Behavior on Titanium Implant Surface Coating with Sintered Hydroxyapatite

Osseointegration is strongly influenced by the physical and chemical characteristics of the implant surfaces, namely topography, roughness profile, and biofunctionalization. The current research assessed the influence of laser surface texturing and hydroxyapatite (HA) biofunctionalization on the viability, morphology,...

Andreia Bandeira Luís, N. Sahoo, B. Fernandes et al. · 0 citations
Open access Oct 2026

Dental implant hemocompatibility: Comparison of two surface treatments

Implant surface topography can influence the initial blood-surface interaction that precedes osseointegration. Therefore, it is of interest to compare the hemocompatibility of 14 commercially available titanium implants with calcium-phosphate-blasted surfaces (Group I, n=7) or alumina-blasted and acid-etched surfaces (...

Shyju Prasad Suresh Babu · 0 citations
Open access Oct 2026

Effect of Surface Treatment Protocols on Nanoindentation-Derived Mechanical Properties and Wettability of Hybrid CAD/CAM Materials

Background/Objectives: Hybrid CAD/CAM materials combine ceramic and polymeric phases, so conditioning protocols developed for glass–ceramics may not transfer to them. Because wettability and near-surface mechanics are usually studied separately, this study measured both to test whether conditioning trades one for the o...

Miloš Todorović, B. Petrović, Stefan Vulović et al. · 0 citations
Sep 2026

Bioinspired Collagen-Zn-PEEK Mixed Interfacial Layer on Color-Stable, Surface-Hardened PEEK for Enhanced Osseointegration.

Although polyetheretherketone (PEEK) offers mechanical advantages over titanium, its clinical utility is often hampered by poor bioactivity and insufficient surface hardness. Drawing inspiration from the natural bone microenvironment, we report a dual-functionalization strategy combining plasma immersion ion implantati...

Lin-Fei Feng, Huan Yang, Shu-Hui Sun et al. · 0 citations
Oct 2026

Surface finish governs HXLPE wear and particle generation in conventional and 3D-printed PEEK hip bearings.

Polyetheretherketone (PEEK) has emerged as a material for all-polymer bearing systems in total hip replacement. However, the influence of surface finishing on the tribological performance of additively manufactured (AM) PEEK remains poorly understood. Wear testing employed a multidirectional pin-on-disc tribometer. Hig...

Benjamin A. Clegg, J. Tipper, N. Emami · 0 citations