Skip to content
Review Open access

Outcomes of Management Strategies for Type Ia Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-analysis.

Sep 2026 · European Journal of Vascular and Endovascular Surgery · 0 citations
Medicine

TL;DR

T1aEL treatment is feasible in selected cases, with apparently acceptable technical and clinical success rates, and F/BEVAR has emerged as the most frequently adopted approach.

Abstract

Objective

This study aimed to systematically review and synthesise the available evidence on the management of type Ia endoleak (T1aEL) after endovascular aortic repair (EVAR). DATA SOURCES MEDLINE, Scopus, Web of Science, and the Cochrane Library. REVIEW

Methods

Studies reporting outcomes of interventions for T1aEL after EVAR were included if they presented cohorts of at least five patients. The certainty of evidence was assessed using the GRADE methodology, while risk of bias was evaluated at the study level using the ROBINS-I v2 tool.

Results

Sixty-three non-randomised studies were included, comprising 2 284 patients (89.0% male, 95% confidence interval [CI] 87.4 - 90.5%) with a weighted mean age of 76.2 years (95% CI 75.30 - 77.02 years). GRADE analysis determined the overall quality of evidence for all outcomes to be very low. The estimated mean interval between index EVAR and T1aEL correction was 47.3 months (95% CI 37.60 - 56.93 months). Overall estimated technical success and clinical success were 95.2% (95% CI 93.9 - 96.4%) and 91.9% (95% CI 90.0 - 93.8%), respectively. Of the 2 284 patients, 1 220 patients underwent fenestrated or branched EVAR (F/BEVAR) (technical success 94.4%, 95% CI 91.6 - 96.8%), 424 open conversion (technical success 94.7%, 95% CI 90.2 - 98.1%), 209 proximal extension (technical success 97.9%, 95% CI 93.9 - 100%), 149 chimney EVAR (technical success 94.1%, 95% CI 88.8 - 98.1%), 117 embolisation (technical success 95.4%, 95% CI 89.7 - 99.2%), 102 endostaples (technical success 76%, 95% CI 39.3 - 99.3%), and 63 physician modified endografts (technical success 97.8%, 95% CI 94.1 - 100%). Estimated overall early mortality was 3.5% (95% CI 2.7 - 4.3%). Endoleak resolution at follow up (mean 19.0 months, 95% CI 16.11 - 21.95 months) was maintained in 96.0% (95% CI 94.6 - 97.3) of patients.

Conclusion

T1aEL treatment is feasible in selected cases, with apparently acceptable technical and clinical success rates. F/BEVAR has emerged as the most frequently adopted approach. Treatment selection should be individualised, taking into account anatomic characteristics, patient fitness, life expectancy, and endoleak specific features.

Read PDF

Similar papers

Review Open access Nov 2026

Fenestrated-Branched Endovascular versus Open Surgical Repair for Elective Thoracoabdominal Aortic Aneurysms: A Systematic Review and Meta-analysis.

OBJECTIVE This study compared outcomes between patients undergoing elective open surgical repair (OSR) and fenestrated branched endovascular aortic repair (FBEVAR) for thoraco-abdominal aortic aneurysms (TAAAs) through a systematic review and meta-analysis. DATA SOURCES PubMed, Embase, and Cochrane. REVIEW METHODS...

Dilson Pimentel-Junior, Milena Monteiro Mastra, Ying Huang et al. · 0 citations
Review Open access Nov 2026

N-Butyl Cyanoacrylate Use for the Management of Type II Endoleak in Endovascular Aortic Repair: A Scoping Review

Objective: Different endovascular techniques are available for type II endoleak management. This scoping review aimed to summarize the available evidence on the use of N-Butyl cyanoacrylate (NBCA) for type II endoleak management. Methods: This review followed the Preferred Reporting Items for Systematic Reviews and Met...

George Apostolidis, P. Nana, G. Panuccio et al. · 0 citations
Review Oct 2026

Non-General Anesthesia for Endovascular Aneurysm Repair: A Systematic Review and Meta-analysis of Clinical Outcomes and Robustness of Evidence.

Current observational evidence supports individualized anesthetic selection rather than proving superiority or equivalence of either technique, and survival estimates are sensitive to study-level characteristics and procedural complexity.

F. Nisi, R. Piscopo, Fabrizio Aurelli et al. · 0 citations
Review Nov 2026

Abstract 4644: Efficacy and Safety of Fenestrated and Branched Endovascular Aortic Repair: A Systematic Review and Meta-Analysis of Global Multi-Center Outcomes in the Modern Era

Objectives: Complex aortic aneurysms involving visceral vessels pose prohibitive surgical risk, driving rapid adoption of fenestrated and branched endovascular aortic repair (F/BEVAR) as a less invasive alternative. Outcomes remain highly variable across single-center experiences, and robust pooled benchmarks are la...

M. H. A. Alhaque Roomi, H. Jawed, Abeeha Fatima et al. · 0 citations
Review Open access Sep 2026

Infection after Endovascular Repair of Complex Aortic and Thoracoabdominal Aneurysms with Fenestrated and Branched Devices: A Systematic Descriptive Review

Endograft infection after fenestrated or branched endovascular aortic repair (F/BEVAR) is an uncommon yet serious complication due to the involvement of the visceral branches and the complexity of the required treatment. This systematic review aimed to descriptively synthesize reported cases of infection after F/BEVAR,...

Andreas L. Tsimpoukis, Christos F. Pitros, F. Efthymiou et al. · 0 citations
Review Open access Oct 2026

Comparative Outcomes of Endovascular and Open Surgical Repair for Extracranial Carotid Artery Aneurysms: A Systematic Review and Meta-analysis.

Observational evidence suggests similar perioperative outcomes and similar observed late event rates for ER and OpR in ECAAs, although heterogeneous follow-up and the absence of time-to-event analyses limit formal comparison of long-term durability.

Mayara Leite Coutinho, Celso Ricardo Bregalda Neves, I. Torres et al. · 0 citations