B-338 Magnetic Bead–Based Sample Preparation for LC–MS/MS Quantification of Steroid Hormones Using PEP Polymer beads

Oct 2026 · Clinical Chemistry · 0 citations

Abstract

Steroid hormones play essential roles in endocrine regulation, reproductive function, immune balance, and metabolic processes. Abnormal steroid profiles are associated with conditions such as congenital adrenal hyperplasia, polycystic ovary syndrome, and adrenal dysfunction. Traditional immunoassays (RIA/ELISA) often suffer from cross reactivity and inaccurate quantification at low concentrations. To address these limitations, an LC–MS/MS workflow utilizing PEP magnetic beads for sample preparation was developed to simultaneously quantify eight clinically relevant steroid hormones in serum PEP MagBeads were used to extract testosterone, progesterone, 11 deoxycortisol, corticosterone, androstenedione, desoxycorticosterone (DOC), dehydroepiandrosterone (DHEA), and pregnenolone from 200 µL serum. Samples were acidified, loaded onto activated magnetic beads, washed with 2% formic acid, and eluted using anhydrous ethanol prior to LC–MS/MS injection. Chromatographic separation was performed on a Kinetex 2.6 µm C18 3×100 mm column, using ammonium fluoride–methanol gradients. MS/MS detection employed MRM in ESI+ mode with compound specific DP and CE optimization. Calibration curves were prepared in defatted bovine serum using matrix matched standards. All eight steroid hormones exhibited excellent linearity across their respective ranges, with correlation coefficients R² = 0.9942, and multiple analytes achieving R² = 1.0000 (testosterone, 11-deoxycortisol, corticosterone). Matrix-spiked bovine serum (2–80 ng/mL) demonstrated strong recovery performance, with average recoveries ranging from 74.6% to 96.9% and precision RSD = 6.6% (n=9). Chromatograms of matrix blanks, standards, and spiked serum showed effective removal of endogenous interferences and clear ion-pair transitions for all target analytes PEP MagBeads provide a robust and efficient magnetic SPE platform for LC–MS/MS quantification of steroid hormones. The method demonstrates high linearity, reproducible recoveries, and strong matrix cleanup, supporting its applicability for clinical and research settings requiring accurate steroid profiling. The simplified preparation workflow and magnetic separation format also make the method suitable for high-throughput or automated laboratory environments

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.