Skip to content
Open access

Negative-polarity-selective non-contact breakup of oppositely charged droplets

Sep 2026 · Experiments in Fluids · Vol 67 · 0 citations · 31 references

Abstract

The non-contact interaction of oppositely charged droplets under strong electric fields involves coupled charge transport, gas ionization, and interfacial instability, yet direct evidence for the origin of polarity-selective breakup remains limited. Here, non-contact breakup of highly conducting oppositely charged droplets was investigated in air and helium using a self-developed microscopic collision platform and high-speed imaging. By varying droplet curvature, reversing the high-voltage-electrode polarity, and comparing acidic and alkaline electrolytes, we show that breakup in air consistently initiates from the negative-polarity droplet. The polarity preference is therefore not governed by droplet geometry, electrode configuration or liquid-phase ion mobility. In helium, the breakup at the negative side becomes weaker, and in some cases, non-contact breakup occurs at both polarity sides. For a given liquid conductivity, the critical nominal electric bond number for breakup is also higher in helium than in air. We suggest that this behavior is associated with gas ionization-mediated space-charge effects in air: Slowly migrating positive ions accumulate near the negatively charged droplet, distort the local electric field and increase the surface charge density until a local sub-Rayleigh instability is reached. In helium, weak electron attachment and faster charged-particle transport reduce this field asymmetry. These results indicate that gas ionization plays an important role in regulating breakup polarity and the dynamic outcome of oppositely charged droplets, providing guidance for electrosprays, microreactors, and electric field-controlled multiphase flows.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.