Sep 2026· International Conference on Artificial Intelligence, Machine, Vision and Control· Vol 14345, pp. 143451W - 143451W-10· 0 citations· 15 references
Engineering
Abstract
Wearable EEG fatigue monitoring requires principled channel selection and robust classification under class imbalance. We introduce a fair per-channel-only ablation protocol for binary fatigue detection—alert (KSS ≤ 6) vs. fatigue (KSS ≥ 7)— applied to 64-channel EEG from 99 real-driving participants (534 trials). Each channel configuration uses only per-channel spectral features (15 per channel), with SelectKBest k scaling linearly with channel count, isolating regional information content from feature-engineering confounds. A cost-sensitive Random Forest with SMOTE oversampling addresses class imbalance. Three findings emerge: (1) a 7-channel prefrontal set (PF-7: Fp1, Fp2, AF3, AF4, AF7, AF8, Fz) achieves 75.0% balanced accuracy—outperforming central channels and retaining 99% of frontal-region performance; (2) theta relative power is the most robust spectral biomarker (76% of channels significant, peak H = 55.4 at Fz), with Spearman correlations confirming alpha increase (ρ = +0.13) and theta decrease (ρ = −0.12) with fatigue; and (3) the cost-sensitive pipeline achieves balanced accuracy of 75.2% with macro-F1 = 0.75 (alert F1 = 0.72, fatigue F1 = 0.78), demonstrating clinically meaningful fatigue detection from real-world driving EEG with minimal preprocessing.
Driver drowsiness is an important contributor to road accidents, but conventional multichannel electroencephalography (EEG) systems are difficult to deploy in everyday driving contexts. This study investigates whether band-power features obtained from a low-cost, single-channel commercial EEG device (NeuroSky MindWave...
Manuel Dominguez-Rodino, M. Civit, M. Dominguez-Morales et al.· Applied Sciences· 0 citations
This study validates entropy-based biomarkers for flow state detection using two wearable EEG headsets, Muse-S and Emotiv Insight, across 45 participants performing adaptive Tetris gameplay and confirmed that entropy biomarkers are robust across diverse modeling frameworks.
Matin Beiramvand, Reijo Koivula, T. Lipping· Biomedical Signal Processing...· 0 citations
Automated sleep staging from single-channel electroencephalography (EEG) may reduce acquisition burden. Limited spatial information and inter-subject variability, however, make prediction difficult.
We evaluated a physiology-informed spectral-temporal framework for single-channel EEG sleep-stage classificati...
Chun-Ming Shih, Bo-Han Lv, Liang-Fan Zhai et al.· Frontiers in Signal Processi...· 0 citations
These findings show cognitive-state-aware safe-stop triggering is implementation-viable, while highlighting the calibration and cross-machine validation needed for deployment, while highlighting the calibration and cross-machine validation needed for deployment.
Sirine Ammar, M. Karray, Mohamed Ksantini· Electronics· 0 citations
Wearable electroencephalography (EEG) seizure detectors must balance detection performance against the cost of extracting and processing large feature sets. This study formulates feature-subset selection as a binary constrained-optimization problem with an explicit latency budget. An imbalance-aware Extreme Gradient Bo...
Hamza Sallam, Aysa Jafarifarmand· 2026 11th International Conf...· 0 citations
Single-channel electroencephalography (EEG) is attractive for wearable neurotechnology and brain–computer interface (BCI) applications, including assistive interfaces and clinical monitoring, but artifact suppression is difficult when auxiliary channels, artifact labels, or user-selected clean baseline segments are una...
Usman Qamar Shaikh, A. Kalra, Andrew Lowe et al.· IEEE transactions on neural...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.