Prefabricated CAD/CAM zirconia membrane versus contour augmentation with early implant placement in the anterior maxilla: a randomized controlled clinical trial
Aug 2026· International Journal of Implant Dentistry· Vol 12· 0 citations· 79 references
Medicine
TL;DR
Customized CAD/CAM zirconia membranes achieved horizontal bone augmentation comparable to conventional collagen membranes when used for simultaneous GBR during early implant placement, indicating that customized rigid barriers may represent a predictable alternative for horizontal ridge augmentation while offering potential advantages in surgical precision and procedural efficiency.
Abstract
Horizontal ridge deficiencies in the anterior maxilla frequently compromise ideal implant positioning and esthetic outcomes. This randomized controlled clinical trial evaluated the clinical performance of customized CAD/CAM zirconia membranes compared with conventional collagen membranes for guided bone regeneration (GBR) performed simultaneously with early implant placement. Twenty systemically healthy patients requiring single-tooth replacement in the anterior maxilla underwent early implant placement (4–8 weeks after tooth extraction) combined with simultaneous contour augmentation using a composite graft of autogenous bone and deproteinized bovine bone mineral (1:1). Participants were randomly assigned to receive either a customized CAD/CAM zirconia membrane (test group, n = 10) or a double-layer collagen membrane (control group, n = 10). The primary outcome was horizontal bone gain (HBG) at 6 months, assessed by standardized CBCT superimposition. Secondary outcomes included soft tissue healing evaluated using the Modified Wound Healing Index (MWHI), membrane exposure (wound dehiscence), and patient-reported postoperative pain assessed using a visual analogue scale (VAS). All implants survived during the 6-month follow-up period (100% survival rate). Mean HBG was 6.18 ± 0.60 mm in the test group and 5.85 ± 0.37 mm in the control group, with no statistically significant difference between groups (p = 0.158). Membrane exposure occurred in all patients receiving customized zirconia membranes (10/10, 100%), whereas no membrane exposure was observed in the collagen membrane group (0/10, 0%). Despite the higher exposure rate, graft stability and horizontal bone regeneration were not adversely affected. Soft tissue healing was significantly more favorable in the collagen membrane group. Postoperative pain decreased significantly over time in both groups, with no significant intergroup differences. Customized CAD/CAM zirconia membranes achieved horizontal bone augmentation comparable to conventional collagen membranes when used for simultaneous GBR during early implant placement. Although customized zirconia membranes were associated with a substantially higher membrane exposure rate, regenerative outcomes and implant survival remained unaffected, indicating that customized rigid barriers may represent a predictable alternative for horizontal ridge augmentation while offering potential advantages in surgical precision and procedural efficiency. Trial registration: ClinicalTrials.gov NCT06987149.
Although extended sticky bone achieved greater immediate postoperative bone volume gain, greater subsequent resorption resulted in comparable clinical and radiographic outcomes between the two groups after 6 months, further studies with larger sample sizes and longer follow-up periods are required to determine the long...
Amira A. M. M. Attia, M. Abass, Mohammed Talaat Salem et al.· BMC Oral Health· 0 citations
Maintaining peri-implant bone and tissue health is essential for long-term implant success. The effectiveness of adjunctive stent stabilization is still unclear, though the apically repositioned flap (ARF) improves soft tissue conditions. Therefore, this study assessed whether the use of stents during single-stage plac...
Ahmed Hamdy, Jazia A. Alblowi, Dalia M. Ghalwash· Saudi Dental Journal· 0 citations
The Bone Ring Technique (BRT) is a newer viable option for restoring complex defects around dental implants with three-dimensional bone augmentation with significant height and width augmentation of buccal bone.
Priyadharshini Annamalai Senthur Pandian, Aniz Amanullah, Lakshmiganthan Mahalingam et al.· Journal of Clinical and Diag...· 0 citations
Immediate implant placement remains challenged by marginal bone loss and peri-implant soft tissue instability despite its clinical advantages. Therefore, it is of interest to evaluate the effectiveness of i-PRF–enhanced bone grafts combined with amniotic membrane in 100 patients undergoing immediate implant placement a...
3D-printed β-TCP biomaterials demonstrated favourable clinical and radiographic outcomes for alveolar ridge regeneration supporting single implant rehabilitation and may provide a predictable alternative for localized alveolar ridge regeneration supporting single implant rehabilitation.
Carlo Mangano, Henriette Lerner, A. Aksu et al.· E -journal of dentistry· 0 citations