Skip to content

Retention-Time Bridging across Gradients for LC-HRMS Feature Correspondence.

Oct 2026 · Journal of the American Society for Mass Spectrometry · Vol 37 11, pp. 2731-2741 · 0 citations · 33 references
Medicine

Abstract

Untargeted liquid chromatography-high-resolution mass spectrometry (LC-HRMS) supports high-throughput metabolomics, but rapid gradients can compress chromatographic separation and limit downstream annotation. A practical annotation strategy is to analyze all samples using a rapid untargeted method and then reinject selected biological and pooled quality-control (QC) samples under a longer-gradient method to improve separation, MS/MS acquisition, and standard-based confirmation. Because short- and long-gradient feature tables cannot be matched reliably by m/z alone, we developed RTBridge, a same-sample, feature-table-based retention-time (RT) bridging workflow that establishes feature correspondence without requiring structural descriptors or quantitative structure-retention relationship models. Unique anchors were selected using within-method mass uniqueness, cross-method mass agreement, and an abundance-concordance score (ACS). Six empirical RT-transfer models were evaluated: linear regression, piecewise linear interpolation, locally estimated scatterplot smoothing (LOESS), piecewise cubic Hermite interpolation (PCHIP), spline/generalized additive modeling (GAM), and monotone GAM. Using all selected mode-specific anchors, PCHIP produced 5,595 primary feature pairs across four matrix/mode data sets, with a mean median RT error of 0.0232 min. GAM-based residual screening reduced the number of selected training anchors from 1,518 to 1,185, primary-pair recovery from 5,595 to 4,867, and verification support from 161 to 151, while decreasing the mean median RT error to 0.0212 min. We therefore recommend PCHIP RT transfer using all selected mode-specific anchors without residual-based hard deletion, followed by abundance-concordance ranking. RTBridge establishes feature correspondence rather than metabolite identification. Potential extensions include platform or column transfer, batch harmonization, cross-matrix correspondence, and interlaboratory integration but will require direct experimental validation.

View source

Similar papers

Open access Oct 2026

Improved Chromatographic Alignment of GC-IMS Data Using Spectral Information

Gas chromatography-ion mobility spectrometry (GC-IMS) provides two-dimensional separation of volatile compounds, but instrumental variability can produce shifts and nonlinear distortions that hinder comparison among measurements. This study presents a chromatographic alignment workflow that uses spectral information fr...

Luis Fernández, Gema del Carmen Guedes de la Cruz, Eduardo Caballero et al. · 0 citations
Review Open access 2026

LC-MS Data Processing Using xcms.

Liquid chromatography-mass spectrometry (LC-MS) is a key technology in metabolomics, enabling high-throughput detection of small molecules across diverse biological samples. However, raw LC-MS data are complex, requiring careful preprocessing to ensure accurate and reproducible feature detection. This chapter introduce...

M. De Graeve, P. Louail, Johannes Rainer · 0 citations
Open access Oct 2026

Parameter-Based Prioritization of Time-Resolved LC–HRMS Ion Tracks for Untargeted Reaction Monitoring

Herein, an automated, parameter-based workflow is introduced for processing time-resolved high-resolution mass spectrometry (HRMS) data. Its utility is demonstrated using the reaction between the ABTS•+ radical cation and the polyphenolic antioxidant naringenin. Data were collected using HRMS coupled to high-performanc...

I. Ilyasov, A. Braun, V. Olicheva et al. · 0 citations
#software testing Review Open access Oct 2026

A Practical Review of Technical Barriers and Solutions on Mass Spectrometry-Based Multi-Attribute Method (MAM) in Biotherapeutics

The multi-attribute method (MAM) is a liquid chromatography–mass spectrometry (LC–MS) platform that combines site-specific quantitation of critical quality attributes (CQAs) with non-targeted new peak detection (NPD) in a single workflow, and can consolidate several conventional chromatographic and electrophoretic assa...

Zhi-Hao Mao, Rachel Kimble, Ervinas Gaidamauskas · 0 citations
Open access 2026

mzmine: Unifying Mass Spectrometry Data Processing.

mzmine 4 introduces substantial improvements in performance, scalability, and usability, enabling the routine analysis of large-scale and multimodal datasets on standard consumer hardware and positioning mzmine 4 as a comprehensive, future-ready platform for untargeted metabolomics and mass spectrometry-based research.

A. Korf, Robin Schmid, S. Heuckeroth et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.