The combination of Strong BGS, water excitation, reference-superimposed processing, and regularized motion correction mitigates motion-related degradation and yields higher-quality perfusion images for high-resolution ASL.
Abstract
Purpose: High resolution arterial spin labeling (ASL)-based perfusion imaging is desirable for many applications but suffers from low SNR and motion sensitivity due to the necessity for highly segmented readouts. Acquisition and reconstruction strategies were optimized for motion-robust high-resolution pseudo-continuous arterial spin labeling (pCASL) of the brain at 3T using segmented 3D Gradient and Spin Echo (3D-GRASE) at 2.0-mm isotropic resolution. Methods: A high-resolution 3D-GRASE pCASL sequence was implemented at 3T and evaluated with a focus on the interaction between background suppression strength and motion-corrected reconstruction, together with the fat suppression and control-tag subtraction strategies that strong suppression requires. Motion correction was performed using a novel motion-compensated (alignedSENSE-based) reconstruction that simultaneously estimates the motion and image, accounting for contrast changes between tag and control data. Eight healthy volunteers were scanned under motion-free and cued motion conditions. Image quality was assessed against motion-free reference images using peak signal-to-noise ratio (PSNR) and a structural similarity index measure (SSIM). Results: The optimized acquisition-reconstruction pipeline enabled robust 2.0-mm isotropic pCASL at 3T and showed improved resistance to motion-related degradation. Strong BGS provided near-complete suppression of static tissue, and water excitation reduced lipid contamination and improved coil sensitivity estimation. The regularized alignedSENSE motion correction further improved perfusion-image quality, increasing SSIM by 18.7% under Strong BGS. Conclusion: Robust high-resolution pCASL at 3T can be achieved through combined optimization of acquisition and reconstruction. The combination of Strong BGS, water excitation, reference-superimposed processing, and regularized motion correction mitigates motion-related degradation and yields higher-quality perfusion images for high-resolution ASL.
PURPOSE
To develop and validate a novel self-gated motion-robust 3D T1-weighted gradient echo imaging framework based on a Cartesian acquisition with spiral profile ordering (CASPR) for abdominal imaging under unstable breath-hold conditions.
METHODS
The CASPR trajectory was evaluated using frequency encoding in the...
Alice Scudeletti, J. Stelter, K. Weiss et al.· Magnetic Resonance in Medici...· 0 citations
PURPOSE
Phase imaging applications such as QSM are highly sensitive to noise amplifications, phase singularities, and other artefacts, particularly in challenging scenarios such as ultra-high field (7 T), under-sampled or single-echo acquisitions. We present a novel image reconstruction method, MORSE-PI, designed to pr...
B. Dymerska, Oliver Josephs, Benjamin T. James et al.· MAGMA· 0 citations
Purpose: Brain MR elastography (MRE) is uniquely sensitive to subject motion, as even small phase deviations can produce large errors in the mechanical properties estimated. Existing motion correction strategies have not been validated for MRE and are often incompatible with complex multi-shot or joint temporal reconst...
Zhuo-Yu Shi, Alex M. Cerjanic, Grace McIlvain· Magnetic Resonance in Medici...· 0 citations
Motion-corrupted inverse problems remain a central bottleneck in magnetic resonance imaging (MRI), especially for high-resolution 3D acquisitions where long readouts couple rigid-body displacement with non-Cartesian k-space sampling. We present a physics-informed implicit neural representation (INR) that recasts 3D mot...
Hao-Yuan Le, Qing Wu, Bo-Wen Li et al.· Medical Image Analysis· 0 citations
BACKGROUND
The left atrium (LA) is a thin structure (1.5-2.5mm). Conventional 3D late gadolinium enhancement (LGE) pulse sequences for imaging the LA typically have limited through-plane resolution (2.5-5mm) or prolonged scan times (10-15min), resulting in poor image quality and limited clinical translatability. We sou...
J. Louis, Kyungpyo Hong, Rupsa Paul et al.· Journal of Cardiovascular Ma...· 0 citations