Skip to content
Review Open access

Tracing Hydrazine in Pharmaceuticals: Toxicological Concerns, Extraction Approaches, and Analytical Method Development

Jan 2026 · Journal of Analytical Methods in Chemistry · Vol 2026 · 0 citations · 40 references
Medicine

TL;DR

Comparative evaluation of the methodologies reveals that combining chemical derivatization with hyphenated techniques delivers the highest sensitivity, and GC‐MS/MS stands out as the gold standard, providing exceptionally low detection limits at the sub‐ppm level with high precision and reliability, while UHPLC‐fluorescence serves as an alternative with considerable sensitivity for detecting hydrazine.

Abstract

Hydrazine (N2H4) is a synthetic reagent that is used in the manufacturing of various active pharmaceutical ingredients (APIs) such as isoniazid, hydralazine, and carbidopa. The major concerns associated with its presence in medications as a residual reagent or degradation product arise because of its ability to damage the genetic material, cause mutations, and potentially trigger cancer. It has been classified under Class 2 genotoxic impurity (GTI), based on the ICH M7 guideline. Its multitissue toxicities including hepatotoxicity, neurotoxicity, and hematotoxicity have led to tight regulatory limits with the EMA threshold of toxicological concern (TTC) at 1.5 µg/day. Detecting hydrazine in trace concentrations is challenging because of its low molecular weight, high polarity, absence of chromophores, and chemical instability. In order to provide a unified framework for impurity profiling, we combine hydrazine’s toxicological profiles, formation pathways, and analytical advancements. Recent advances on the extraction, derivatization, and analytical determination of hydrazine to improve its stability and detectability in pharmaceutical matrices ranging from 2020 to 2025 were collected. Comparative evaluation of the methodologies reveals that combining chemical derivatization with hyphenated techniques delivers the highest sensitivity. GC‐MS/MS stands out as the gold standard, providing exceptionally low detection limits at the sub‐ppm level with high precision and reliability, while UHPLC‐fluorescence serves as an alternative with considerable sensitivity for detecting hydrazine. Gaps in method harmonization, reference standard availability, and validation for complex formulations still remain therefore future work should focus more on standardized analytical methods, development of greener methods of derivatization, as well as use of high‐resolution detection systems.

Read PDF

Similar papers

Review Open access Oct 2026

N-NITROSAMINE IMPURITIES IN PHARMACEUTICALS: FORMATION PATHWAYS, TOXICOLOGICAL CONCERNS, REGULATORY APPROACHES AND RISK MITIGATION STRATEGIES

Background: N-nitrosamine impurities represent an important pharmaceutical quality and patient safety concern because several members of this chemical class exhibit mutagenic and carcinogenic potential. Objective: To synthesize scientific and regulatory evidence concerning their formation, toxicological assessment, an...

S. Alaoui, A. C. Chefchaouni, B. Moukafih et al. · 0 citations
Open access Sep 2026

Nitrosoamine Impurities: Current Status, Challenges and Future Perspectives

Nitrosamines are zwitterionic resonance structures which are bioactivated by cytochrome P450 into reactive diazonium ions, which form carcinogenic DNA adducts, especially O6-methylguanine, leading to mutations and epigenetic silencing of tumour suppressor genes.

Sarupruthiya M, Jeevitha D, V. S et al. · 0 citations
Review Open access Oct 2026

Toxicological insights and health risks of Didecyldimethylammonium Chloride (DDAC): an integrative review.

Didecyldimethylammonium chloride (DDAC) is a broad-spectrum quaternary ammonium compound (QAC) extensively utilized as a disinfectant and biocide. Widespread use of DDAC, significantly amplified during COVID-19 pandemic, increased human and environmental exposures, indicating need for updated, quantitative risk assessm...

Eun Ah Lee, Jae Hyeon Park, S. Kwack et al. · 0 citations
Review Open access Jan 2026

Recent Analytical Methods for N-Nitrosamine Analysis as Impurities in Drug Substances and Drug Products

N‐nitrosamine (hereinafter nitrosamine) is among the organic impurities characterized by high potency as genotoxic and probable human carcinogens found in drug substances and drug products. This type of impurity has become a major concern in pharmaceutical industry, since one of nitrosamine type of impurities, NDMA, wa...

Rimadani Pratiwi, Alifa Dhia Shalima, Mutakin et al. · 0 citations
Review Oct 2026

Molecular Toxicological Mechanisms of Pharmaceutical Nitrosamines: DNA Damage, Metabolic Activation, Carcinogenesis, and Advanced Analytical Detection Strategies.

In light of the valsartan recalls in 2018, nitrosamine impurities have become some of the most important pharmaceutical quality concerns to be seen in recent years, as NDMA and other nitrosamines have been discovered in angiotensin receptor blockers, metformin, ranitidine, and many other medicines. Nitrosamine impuriti...

Pradip Karale, Vishal Chabukswar, Ishvari Avachar et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.