CSP, and potentially LBBAP, was associated with a significantly lower composite endpoint of HHF and all-cause mortality compared with BiVP, supporting CSP as an alternative to BiVP in HF.
Abstract
Background
Conduction system pacing (CSP) has emerged as a promising modality for cardiac resynchronization therapy, but evidence of CSP in heart failure (HF) remains controversial.
Objectives
The authors aimed to compare the efficacy and safety of CSP, including left bundle branch area pacing (LBBAP) and His bundle pacing, to biventricular pacing (BiVP) in HF.
Methods
The MEDLINE, EMBASE, and CENTRAL databases were searched from inception until May 2026. The primary endpoint was a composite of hospitalization for heart failure (HHF) and all-cause mortality. Secondary endpoints included clinical endpoints (HHF, all-cause mortality), cardiac resynchronization therapy responses (predefined and super-response), echocardiographic parameters (left ventricular ejection fraction and left ventricular end-systolic volume), electrophysiologic parameters (paced QRS duration and capture threshold), functional status (NYHA functional class and 6-minute walk test distance), procedural performance (procedural time, fluoroscopy time, lead implantation time), and device-related complications. (PROSPERO registration: CRD420261388077).
Results
Twelve randomized controlled trials involving 1,054 patients (566 CSP and 488 BiVP) were included. CSP showed a significant reduction in primary composite endpoint (OR: 0.30; 95% CI: 0.18-0.52; I2 = 0%), improvement in left ventricular ejection fraction (mean difference: 3.06%; 95% CI: 0.82%-5.30%; I2 = 55%), and shorter paced QRS duration (mean difference:-11.49 ms; 95% CI: -20.70 to -2.28; I2 = 85%), compared with BiVP. In the LBBAP group, there were greater reductions in primary composite endpoint with higher rates of super-response (OR: 2.18; 95% CI: 1.44-3.30; I2 = 54%) compared with BiVP. No differences were observed in functional status or device-related complications.
Conclusions
CSP, and potentially LBBAP, was associated with a significantly lower composite endpoint of HHF and all-cause mortality compared with BiVP, supporting CSP as an alternative to BiVP in HF.
Conventional right ventricular pacing (RVP) is associated with an increased risk of pacing-induced cardiomyopathy, heart failure (HF), and atrial fibrillation. While conduction system pacing (CSP) - comprising His-bundle and left bundle branch area pacing (LBBAP) - has emerged as a promising physiological alterna...
M. Bistriceanu, C. Ursu, A. Deaconu et al.· European Heart Journal· 0 citations
BACKGROUND
Left bundle branch area pacing (LBBAP) has emerged as an alternative to conventional biventricular pacing (BiVP) for cardiac resynchronization therapy (CRT). While observational studies have suggested potential advantages of LBBAP in some domains. However, recent randomized controlled trials (RCTs) have repo...
Hassaan Imtiaz, A. Costa, A. Mohammed et al.· Pacing and clinical electrop...· 0 citations
In HF patients with refractory AF undergoing atrioventricular node ablation, CSP with left bundle branch area pacing was non-inferior to BVP for LVEF improvement at 6 months, providing comparable clinical outcomes and a favourable procedural profile.
D. Žižek, M. Ivanovski, M. Mrak et al.· European Heart Journal· 0 citations
BACKGROUND
Conduction system pacing (CSP) via left bundle branch area pacing (LBBAP) is a physiologic alternative to conventional biventricular (BiV) pacing for cardiac resynchronization therapy (CRT), but prospective data using purpose-built implantable cardioverter-defibrillator (ICD) leads are limited.
OBJECTIVES...
N. Varma, H. Burri, Alvaro Manrique-Garcia et al.· JACC Clinical Electrophysiol...· 0 citations
Conventional right ventricular pacing (RVP) is associated with electromechanical dyssynchrony and may contribute to pacing-induced cardiomyopathy (PICM). Left bundle branch area pacing (LBBAP) has emerged as a physiological pacing strategy that engages the native conduction system. This review summarizes the current cl...
G. Leventopoulos, R. Koros, M. Derndorfer et al.· Hellenic Journal of Cardiolo...· 0 citations
Background Failure to achieve effective cardiac resynchronisation therapy (CRT) remains a clinically significant challenge, often driven by anatomical constraints or suboptimal left ventricular lead performance. Conduction system pacing (CSP), incorporating His bundle pacing and left bundle branch area pacing, has emer...
K. Thu, I. Antoun, K. Z. Thant et al.· Frontiers in Physiology· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.