Skip to content
Open access

X-ray image quality before and after radiographer commenting: A quantitative visual grading characteristics analysis.

Oct 2026 · Radiography · Vol 32 8, pp. 103587 · 0 citations · 46 references
Medicine

TL;DR

Quantitative evidence demonstrates implementation of RCA significantly improves the overall quality of projection radiographs submitted for reporting.

Abstract

INTRODUCTION The Radiographer Comment and Alert (RCA) model was established to provide written alerts of abnormal radiographic appearances identified at acquisition, but its quantitative impact on image quality is unknown. This study quantifies differences in radiograph image quality before and after RCA implementation.

Methods

A total of 234 radiographs encompassing the pelvis, hand, wrist, elbow, knee, ankle, and foot were collected. This comprised all 117 investigations for these anatomical areas with radiographer comments over 12-months at one site, and 117 matched radiographs obtained one year before RCA implementation. Each image pair was displayed simultaneously, but the order and left-right orientation was randomised. Seventeen radiographers independently rated image pairs using a visual grading characteristics (VGC) analysis scale on seven quality criteria (rotation, angulation, centering, collimation, exposure, artifacts, diagnostic utility). Data were analysed using VGC Analyser Software v1.0.2. Non-parametric rank-invariant statistics generated an area under the VGC curve (AUCVGC) to measure the difference in quality between images with and without radiographer comments.

Results

Across the combined dataset, images acquired after implementation of RCA received visual grading ratings for radiological quality that were significantly higher than images acquired prior to implementation (AUCVGC0.52, p = 0.016, CI[0.500862,0.532967]). Statistical significance at 95% confidence was not met for individual upper (AUCVGC0.52, p = 0.084) and lower limb (AUCVGC0.50, p = 0.746) regions, but was achieved for the axial region (AUCVGC0.54, p = 0.012). Quality improvement was driven by improved positioning, particularly rotation (AUCVGC0.57, p = 0.002). Intraclass correlation coefficient scores were good or excellent (ICC3,k ≳ 0.62-0.97) and all reached significance (p-value<0.05), indicating stable consensus and good inter-rater agreement.

Conclusion

Quantitative evidence demonstrates implementation of RCA significantly improves the overall quality of projection radiographs submitted for reporting. IMPLICATIONS FOR PRACTICE Radiographer image interpretation models can be utilised as tools to improve radiographic image quality.

Read PDF

Similar papers

Open access Oct 2026

Subjective and objective image quality evaluation of a scatter correction algorithm applied to hip radiographs.

INTRODUCTION Hip radiographs are common examinations but are technically challenging because of variable patient body habitus and anatomy. Physical anti-scatter grids improve contrast but increase radiation dose and introduce practical limitations, particularly in trauma and mobile imaging. Software-based scatter corre...

Hoi-Ching Cheung, R. Meertens, Man-Ning Fay et al. · 0 citations
Open access Oct 2026

Digital image display manipulation and observer variability in pediatric chest radiograph interpretation

Background: Interpretation of pediatric chest radiographs is subject to observer variability, and digital image processing may further influence visual assessment. We evaluated interobserver agreement and the effect of controlled contrast manipulation on the interpretation of pediatric chest radiographs. Methods: Sixty...

Chrislip James, D. Narayanasamy, V. Tanigasalam et al. · 0 citations
Open access Nov 2026

Patient Positioning Techniques for Improved Radiographic Image Quality in Dentistry: An Evaluation of Intraoral and Panoramic Radiography

High-quality dental radiographs are essential for accurate diagnosis, treatment planning, and prognostic assessment. Technical errors in patient positioning represent the leading cause of non-diagnostic image quality, leading to unnecessary ionizing radiation exposure through repeat exposures. To perform an empirical s...

M. Abour · 0 citations
Open access Nov 2026

Prevalence of Radiographic Errors and Assessment of Diagnostic Image Quality in Panoramic Radiographs: A Retrospective Study

Background/Objectives: Panoramic radiography is an important imaging modality for the evaluation of dentoalveolar and maxillofacial structures in dental diagnosis and treatment planning. The diagnostic quality of panoramic images is closely related to appropriate patient preparation and accurate positioning. Positionin...

Fatoş Can, F. Kalabalık, Emre Haylaz et al. · 0 citations
Open access Sep 2026

Quality assessment of radiographs through AI-driven feedback: A randomized comparative study on radiographer response in lateral knee radiographs.

INTRODUCTION High-quality radiographic positioning is essential for accurate diagnosis in knee imaging. Although artificial intelligence (AI) can assess image quality with high accuracy, its influence on radiographers' clinical decision-making remains unclear. This study examined whether AI feedback affects radiographe...

S. Lysdahlgaard, J. Jensen, M. R. Pedersen et al. · 0 citations
Open access Oct 2026

Effect of Image Enhancement Filters on the Detection of Periapical Radiolucent Lesions on Panoramic Radiographs: A Multi-Reader Multi-Case Study

Background: Panoramic radiography is widely used in dental practice, but its two-dimensional projection geometry and anatomical superimposition can obscure periapical radiolucent lesions, particularly in the maxillary anterior region and for novice observers. Methods: This retrospective multi-reader, multi-case study a...

Ö. B. Doğan, Hatice Biltekin · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.